Brake Actuator: Inspection
- CHECK BRAKE ACTUATOR ASSEMBLY
- Measure the resistance according to the value (s) in the table below.
HINT:
Perform the check with the actuator at the lowest temperature possible.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition 20 (SMC1)-19 (BS1) Always 15.3 to 25.0 Ω 6 (SMC2) - 7 (BS2) 8 (SLAFR+) - 5 (SLAFR-) 3.6 to 6.0 Ω 22 (SLRFR+) - 21 (SLRFR-) 13 (SLAFL+)-14 (SLAFL-) 27 (SLRFL+) - 28 (SLRFL-) 12 (SLARR+) -11 (SLARR-) 10 (SLARL+)-9 (SLARL-) 26 (SLRRR+) - 25 (SLRRR-) 4.4 to 7.0 Ω 24 (SLRRL+) - 23 (SLRRL-) If the result is not as specified, replace the brake actuator.
- Measure the resistance according to the value (s) in the table below.
- CHECK BRAKE ACCUMULATOR PUMP
- Measure the resistance according to the value (s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition A2 (BM1)-A4 (GND1) Always 10 kΩ or higher B2 (BM2)-A4 (GND1) A2 (BM1)-B2 (BM2) Below 1 Ω A4 (GND1)-B1 (GND2) A2 (BM1)-A1 (MTT) 950 to 1050 Ω B2 (BM2) - A1 (MTT) If the result is not as specified, replace the brake accumulator pump.
- Measure the resistance according to the value (s) in the table below.