Data List / Active Test
- DATA LIST
HINT:
Using the intelligent tester or Techstream to read the Data List allows the values or states of switches, sensor, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.- Warm up the engine.
- Turn the engine switch off.
- Connect the intelligent tester or Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus:
- Intelligent tester - Select: DIAGNOSIS / OBD/ MOBD / ELEC PWR CTRL / DATA LIST / ALL /
- Techstream - Select: Body Electrical / Electric Power Control / Data List /
- According to the display on tester, read the "Data List".
- Intelligent tester
ELEC PWR CTRL
DATA LIST REFERENCE (ELEC PWR CTRL)Tester Display Measurement Item/Range Normal Condition Diagnostic Note Freeze DTC - - - CHARGE CURRENT Current battery current value display/ Min.: -300, Max.: 100 [A] Amperage value is displayed - BATTERY TEMP Current battery temperature value display/ Min.: -30, Max.: 90 [°C] Temperature near battery is displayed - BATTERY VOL Current battery voltage value display/ Min.: 0, Max.: 16.67 [V] Battery voltage is displayed - IG2 SIGNAL - - - ENG SW SIGNAL - - - PWR CUT SIGNAL Condition of relay (which cuts part of vehicle's power) display/ ON or OFF ON: Power supply supplied
OFF: Power supply cut- CHG WARN RQST - - - WIPER MOTOR - - - ENG RUNNING - - - ALT GEN VOLTAGE - - - ALT GEN RATE - - - ENGINE SPEED - - - INTAKE AIR TEMP - - - COOLANT TEMP - - - IG SIGNAL - - - ACC SIGANL - - - HOOD COURTSY SW - - - D COURTSY SW - - - P COURTSY SW - - - RR COURTSY SW - - - RL COURTSY SW - - - LUGG COURTSY SW - - - TAIL LIGHT - - - LIGHT/COMBI SW - - - EPS CUR ASSIST - - - ENA EPS CUR AST - - - LMT EPS CUR AST - - - PROHIBIT CHARGE - - - A/C CONSUMPTION - - - PCS ACT SIGNAL - - - ENA ENG SPD SIG - - - VEHICLE SPEED - - - STARTUP STATUS - - - GENERATE RQST - - - CHG MODE-ECM - - - CHG MODE-ELEC - - - RQST PRHBT CHG1 - - - RQST IDLE UP - - - RQST ADJ ALT V - - - RQST PRHBT CHG2 - - - RUN-AV B TEMP - - - INT-CUR CTL CHG - - - BAT VOLTAGE LOW Battery voltage drop judgment display/ ON or OFF ON: Dropped
OFF: NormalMeter display is shown CNTRL LD LVL 3 Electrical equipment operation limit display/ ON or OFF ON: During electrical equipment operation limit
OFF: No electrical equipment operation limitMeter display is shown VOLTAGE DETECTN Battery voltage detection path malfunction display/ ON or OFF ON: Malfunctioning
OFF: NormalMeter display is shown ALT FAILURE Display for generator malfunction or charging line malfunction/ ON or OFF ON: Malfunctioning
OFF: NormalMeter display is shown CNTRL LOAD LVL Current load control level display/ 0 to 3 0: No control
1: Load control level 1
3: Load control level 3Load control level 2 is not displayed RQST EPS LIMIT EPS current consumption limit request display/ 0 to 1 0: No request is made
1: Request is made- RQST A-SUSP LMT Air suspension current consumption limit request display ON or OFF ON: No request is made
OFF: Request is made- AVG BATT CURRNT - - - AVG BATT VOLT - - - AVG BAT VOLT-5S - - - AVG BAT CURR-5S - - - AVG BAT CURR-LD - - - AVG BAT VOLT-LD - - - JUMP START - - - DSCHG DET-ST - - - DSCHG DTCT-EPS - - - DSCHG HIST-ST - - - ENG RUN STATUS - - - DSCHG UPD-EPS - - - DSCHG HIST-EPS - - - INTERNAL RESIST - - - INT RESIST-CALC - - - V OPEN CIR VOLT - - - V OPN VOLT-CALC - - - CHRG RATE START - - - RQST GEN STATUS - - - INT-CUR CHG CTL - - - A CHG N-END - - - R CHG N-END - - - R CHRG ABN END - - - BAT VOLT STABIL - - - BAT CUR STABIL - - - R CHG ABN END # - - - INT RESIST 25°C - - - RUN-AV ALT DTY1 - - - RUN-AV ALT DTY2 - - - PARKING TIME - - - POWER CUT OVER - - - LIMIT CUR-PCS - - - LIMIT CUR-EPS - - - DCHG CUR-EPS - - - DCHG CUR-PCS - - - RQST CTL LD1-L - - - RQST CTL LD2-L - - - RQST CTL LD-PCS - - - RQST CTL LD-EPS - - - RQST LMT-F - - - RQST LMT1 EPS-L - - - RQST LMT2 EPS-L - - - RQST LMT2 EPS-F - - - RQST LMT PCS - - - RQST LMT EPS - - - RQST LMT ASUS-F - - - RQST CTL LD3-L - - - RQST LMT3 EPS-L - - - H-CTL LD LV1 Load control level 1 history count/ 0 to 255 History count until now - H-CTL LD LV3 Load control level 3 history count/ 0 to 255 History count until now - H-RQST CTL LD-F Load control operation history display (when charging system is malfunctioning)/ ON or OFF ON: Operation history is present
OFF: No operation history- H-RQST CTL EPS Load control operation history display (during EPS operation)/ ON or OFF ON: Operation history is present
OFF: No operation history- H-RQST CTL PCS Load control operation history display (during PCS operation)/ ON or OFF ON: Operation history is present
OFF: No operation history- H3-RQST CTL LD Load control operation history display (when battery voltage is low)/ ON or OFF ON: Operation history is present
OFF: No operation history- H2-RQST CTL LD Load control operation history display (when battery voltage is low)/ ON or OFF ON: Operation history is present
OFF: No operation history- H1-RQST CTL LD Load control operation history display (when battery voltage is low)/ ON or OFF ON: Operation history is present
OFF: No operation history- H-VOL CTL LD Battery voltage value display (when load control is performed)/ Min.: 0, Max.: 16.67 [V] Battery voltage value when load control is performed is displayed - H-CUR CTL LD Battery current value display (when load control is performed)/ Min.:-300, Max.: 100 [A] Battery current value when load control is performed is displayed - H-BAT TEMP Battery temperature value display (when load control is performed)/ Min.:-150, Max.: 150 [°C] Battery temperature value when load control is performed is displayed - H-V OPN VOL Battery virtual open-circuit voltage value display (when load control is performed)/ Min.: 0, Max.: 16.67 [V] Battery virtual open-circuit voltage value when load control is performed is displayed - H-INT RESIST Battery interior resistance value display (when load control is performed)/ Min.: 0, Max.: 120 [mΩ] Battery interior resistance value when load control is performed is displayed - #CODES Number of trouble code - - - Techstream
Electric Power Control
DATA LIST REFERENCE (ELECTRIC POWER CONTROL)Tester Display Measurement Item/Range Normal Condition Diagnostic Note Electrical Charge Current Current battery current value display/ Min.:-300, Max.: 100 [A] Amperage value is displayed - Battery Temperature Current battery temperature value display/ Min.: -30, Max.: 90 [°C] Temperature near battery is displayed - Battery Voltage Current battery voltage value display/ Min.: 0, Max.: 16.67 [V] Battery voltage is displayed - IG2 Signal - - - Engine Switch Signal - - - Power Cut Signal Condition of relay (which cuts part of vehicle's power) display/ ON or OFF ON: Power supply supplied
OFF: Power supply cut- Charge Warning Request - - - Wiper Motor - - - Engine Run - - - Alternator Gen Voltage - - - Alternator Gen Rate - - - Engine Speed - - - Intake-Air Temp - - - Coolant Temp - - - IG Signal - - - ACC Signal - - - Hood Courtesy Switch - - - D Side Door Courtesy SW - - - P Side Door Courtesy SW - - - Rear Door Courtesy SW RH - - - Rear Door Courtesy SW LH - - - Luggage Courtesy Switch - - - Tail Light - - - Light and Combi SW Status - - - EPS Cur on Assist - - - EPS Cur Enable on Assist - - - Limit Assist EPS Current - - - Prohibit to Charge - - - A/C Elec Pwr Consumption - - - PCS Actuation Signal - - - Engine Speed Signal Enable - - - Vehicle Speed - - - Startup Elec Pwr Ctrl Status - - - Gen Request - - - Ctrl Chg Mode from ECM - - - Ctrl Chg Mode in Elec - - - Request to Prohibit Charge 1 - - - Request to Idle Up - - - Req Adjust Alternator Vol - - - Request to Prohibit Charge 2 - - - Run Avg Bat Temp - - - Integ Cur Val to Ctrl Chg - - - Battery Voltage Low Battery voltage drop judgment display/ ON or OFF ON: Dropped
OFF: NormalMeter display is shown Control Load Level 3 Electrical equipment operation limit display/ ON or OFF ON: During electrical equipment operation limit
OFF: No electrical equipment operation limitMeter display is shown Voltage Detection Battery voltage detection path malfunction display/ ON or OFF ON: Malfunctioning
OFF: NormalMeter display is shown Alternator Failure Display for generator malfunction or charging line malfunction/ ON or OFF ON: Malfunctioning
OFF: NormalMeter display is shown Control Load Level Current load control level display/ 0 to 3 0: No control
1: Load control level 1
3: Load control level 3Load control level 2 is not displayed Request to Limit EPS EPS current consumption limit request display/ 0 to 1 0: No request is made
1: Request is made- Req Limit Air Suspension Air suspension current consumption limit request display/ ON or OFF ON: No request is made
OFF: Request is made- Run Avg Bat Cur - - - Run Avg Bat Vol - - - Avg Bat Vol During 5 Sec - - - Avg Bat Cur During 5 Sec - - - Run Avg Bat Vol - - - Run Avg Bat Cur - - - Jump Start - - - Dischg Detect (Start) - - - Dischg Detection (EPS) - - - Dischg Update Hist (Start) - - - Engine Run Status - - - Dischg Update (EPS) - - - Discharge Upd Hist (EPS) - - - Internal Resistance - - - Int Resist Calc Dischg Cur - - - Virtual Open Circuit Voltage - - - Virtual Opn Circuit Vol - - - Charging Rate (Start) - - - Req Gen Status - - - Integ Cur Chg Ctrl - - - Assist Charge Normal End - - - Refresh Charge Normal End - - - Refresh Charge Abend - - - Bat Vol Stabilization - - - Bat Cur Stabilization - - - Num of Refresh Chg Abend - - - Internal Resistance (25C) - - - Run Avg Alt Duty - - - Run Avg Alt Dty - Ctrl Chg - - - Parking Time - - - Power Cutover Status - - - Limit Current (PCS) - - - Limit Current (EPS) - - - Discharge Current (EPS) - - - Discharge Current (PCS) - - - Req Ctrl Load 1 - Low Vol - - - Req Ctrl Load 2 - Low Vol - - - Req Ctrl Load (PCS) - - - Req Ctrl Load (EPS) - - - Req Limit - Failure - - - Req Limit EPS 1 - Low Vol - - - Req Limit EPS 2 - Low Vol - - - Req Limit EPS 2 - Failure - - - Req Limit Air Sus - PCS ON - - - Req Limit EPS - Air Sus ON - - - Req Limit Air Sus - Failure - - - Req Limit Load 3 - Low Vol - - - Req Limit EPS 3 - Low Vol - - - Ctrl Load Lv1 History Load control level 1 history count/ 0 to 255 History count until now - Ctrl Load Lv3 History Load control level 3 history count/ 0 to 255 History count until now - Req Ctrl Load on Fail Hist Load control operation history display (when charging system is malfunctioning)/ ON or OFF ON: Operation history is present
OFF: No operation history- Req Ctrl Load on EPS Hist Load control operation history display (during EPS operation)/ ON or OFF ON: Operation history is present
OFF: No operation history- Req Ctrl Load on PCS Hist Load control operation history display (during PCS operation)/ ON or OFF ON: Operation history is present
OFF: No operation history- Req Ctrl Load Hist 3 Load control operation history display (when battery voltage is low)/ ON or OFF ON: Operation history is present
OFF: No operation history- Req Ctrl Load Hist 2 Load control operation history display (when battery voltage is low)/ ON or OFF ON: Operation history is present
OFF: No operation history- Req Ctrl Load Hist 1 Load control operation history display (when battery voltage is low)/ ON or OFF ON: Operation history is present
OFF: No operation history- Hist-Bat Vol for Ctrl Load Battery voltage value display (when load control is performed)/ Min.:0, Max.: 16.67 [V] Battery voltage value when load control is performed is displayed - Hist-Bat Cur for Ctrl Load Battery current value display (when load control is performed)/ Min.:-300, Max.: 100 [A] Battery current value when load control is performed is displayed - Bat Temp Hist Battery temperature value display (when load control is performed)/ Min.:-150, Max.: 150 [°C] Battery temperature value when load control is performed is displayed - Virtual Opn Circuit Vol Hist Battery virtual open-circuit voltage value display (when load control is performed)/ Min.: 0, Max.: 16.67 [V] Battery virtual open-circuit voltage value when load control is performed is displayed - Internal Resistance Hist Battery interior resistance value display (when load control is performed)/ Min.: 0, Max.: 120 [mΩ] Battery interior resistance value when load control is performed is displayed - # Codes Number of trouble code - -
- Intelligent tester
- ACTIVE TEST
HINT:
Using the intelligent tester or Techstream to perform the Active Tests allows relays, VSVs and actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
- Warm up the engine.
- Turn the engine switch off.
- Connect the intelligent tester or Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus:
- Intelligent tester - Select: DIAGNOSIS / OBD/ MOBD / ELEC PWR CTRL / ACTIVE TEST /
- Techstream - Select: Body Electrical / Electric Power Control / Active Test /
- According to the display on tester, perform the "Active Test".
- Intelligent tester
ELEC PWR CTRL
ACTIVE TEST REFERENCE (ELEC PWR CTRL)Tester Display Test Part Control Range PWR CUT RELAY When OFF, power cut linked parts cannot be used ON / OFF LIMIT LOAD LVL Limit control is performed on heater related load control linked systems 0/ 1/ 3 LMT EPS Limit control is performed on current for EPS assist ON / OFF LIMIT AIR SUSP Limit control is performed on air suspension compressor operation ON / OFF - Techstream
Electric Power Control
ACTIVE TEST REFERENCE (ELECTRIC POWER CONTROL)Tester Display Test Part Control Range Activate Power Cut Relay When OFF, power cut linked parts cannot be used ON / OFF Limit Load Level Limit control is performed on heater related load control linked systems 0/1/3 Request to Limit EPS Limit control is performed on current for EPS assist ON / OFF Request to Limit Air Suspension Limit control is performed on air suspension compressor operation ON / OFF
- Intelligent tester