Intake Air Control Valve Actuator: Inspection
- INSPECT INTAKE AIR CONTROL VALVE ACTUATOR
- When battery voltage is applied between terminals 1 and 2 of the connector, check the operation of the actuator shaft.
Standard
TERMINALS VOLTAGE CHARTTerminal Number (Battery Terminal) Specified Condition 1 (battery terminal +) - 2 (battery terminal -) Actuator shaft rotates to left 1 (battery terminal -) - 2 (battery terminal +) Actuator shaft rotates to right NOTE: Apply battery voltage for 10 seconds or less each time the inspection is performed.
- When battery voltage is applied between terminals 1 and 2 of the connector, check the operation of the actuator shaft.