Diagnostic Procedure
- CHECK OVERALL FUNCTION
- Turn ignition switch ON.
- Pinch fuel feed hose with two fingers.
Fuel pressure pulsation should be felt on the fuel feed hose for 1 second after ignition switch is turned ON.
OK or NG
OK: INSPECTION END
NG: GO TO 2.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-I
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Turn ignition switch ON.
- Check voltage between ECM terminal 113 and ground with CONSULT-II or tester.
Voltage: Battery voltage
OK or NG
OK: GO TO 5.
NG: GO TO 3.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-II
Check voltage between IPDM E/R terminal 46 and ground with CONSULT-II or tester.
Voltage: Battery voltage
OK or NG
OK: GO TO 4.
NG: GO TO 12.
- DETECT MALFUNCTIONING PART
Check harness for open or short between IPDM E/R and ECM
: Repair harness or connectors.
- CHECK FUEL PUMP POWER SUPPLY CIRCUIT-III
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Disconnect "fuel level sensor unit and fuel pump" harness connector.
- Turn ignition switch ON.
- Check voltage between "fuel level sensor unit and fuel pump" terminal 1 and ground with CONSULT-II or tester.
Voltage: Battery voltage should exist for 1 second after ignition switch is turned ON.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 9.
NG: GO TO 6.
- CHECK 15A FUSE
- Turn ignition switch OFF.
- Disconnect 15A fuse.
- Check 15A fuse.
OK or NG
OK: GO TO 7.
NG: Replace fuse.
- CHECK FUEL PUMP POWER SUPPLY CURCUIT-IV
- Disconnect IPDM E/R harness connector E119.
- Check harness continuity between "fuel level sensor unit and fuel pump" terminal 1 and IPDM E/R terminal 13.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 12.
NG: GO TO 8.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness for open or short between "fuel level sensor unit and fuel pump" and IPDM E/R
: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP GROUND CIRCUIT FOR OPEN AND SHORT
- Check harness continuity between "fuel level sensor unit and fuel pump" terminal 3 and ground.
Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to ground.
OK or NG
OK: GO TO 11.
NG: GO TO 10.
- Check harness continuity between "fuel level sensor unit and fuel pump" terminal 3 and ground.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness for open or short between "fuel level sensor unit and fuel pump" and ground
: Repair open circuit or short to power in harness or connectors.
- CHECK FUEL PUMP
Refer to "COMPONENT INSPECTION "
OK or NG
OK: GO TO 12.
NG: Replace fuel pump.
- CHECK INTERMITTENT INCIDENT
Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT "
OK or NG
OK: Replace IPDM E/R.
NG: Repair or replace harness or connectors.