With CONSULT-II 

  1. Reconnect harness connectors disconnected.
  2. Turn ignition switch ON.
  3. Perform "VIAS SOL VALVE" in "ACTIVE TEST" mode.
  4. Check air passage continuity and operation delay time under the following conditions.
    AIR PASSAGE CONTINUITY CHART (1 OF 2)

    Condition VIAS SOL VALVE Air passage continuity between A and B Air passage continuity between A and C
    ON Yes No
    OFF No Yes

    Operation takes less than 1 second  .

    Fig 1: CONSULT-II Display - Active Test
    G04897282Courtesy of NISSAN MOTOR CO., U.S.A.

Without CONSULT-II 

Check air passage continuity and operation delay time under the following conditions.

AIR PASSAGE CONTINUITY CHART (2 OF 2)

Condition Air passage continuity between A and B Air passage continuity between A and C
12V direct current supply between terminals 1 and 2 Yes No
No supply No Yes

Operation takes less than 1 second  .

Fig 2: Checking Air Passage Continuity And Operation Delay Time
G04897283Courtesy of NISSAN MOTOR CO., U.S.A.