Diagnostic Procedure
WARNING: This page is about a different car, the 2004 Nissan Quest. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK OVERALL FUNCTION
WITH CONSULT-II
- Start engine and warm it up to normal operating temperature.
- Perform "VIAS SOL VALVE" in "ACTIVE TEST" mode with CONSULT-II.
- Turn VIAS control solenoid valve ON and OFF, and make sure that power valve actuator rod moves.
Without CONSULT-II
- Start engine and warm it up to normal operating temperature.
- Rev engine quickly up to above 5,000 RPM and make sure that power valve actuator rod moves.
OK or NG
- OK: INSPECTION END
- NG (With CONSULT-II): GO TO 2.
- NG (Without CONSULT-II): GO TO 3 .
- CHECK VACUUM EXISTENCE
WITH CONSULT-II
- Stop engine and disconnect vacuum hose connected to power valve actuator.
- Start engine and let it idle.
- Perform "VIAS SOL VALVE" in "ACTIVE TEST" mode with CONSULT-II.
- Turn VIAS control solenoid valve ON and OFF, and check vacuum existence under the following conditions.
OK or NG
- OK: Repair or replace power valve actuator.
- NG: GO TO 4 .
- CHECK VACUUM EXISTENCE
Without CONSULT-II
- Stop engine and disconnect vacuum hose connected to power valve actuator.
- Disconnect VIAS control solenoid valve harness connector.
- Start engine and let it idle.
- Apply 12V of direct current between VIAS control solenoid valve terminals 1 and 2.
- Check vacuum existence under the following conditions.
OK or NG
- OK: Repair or replace power valve actuator.
- NG: GO TO 4.
- CHECK VACUUM HOSE
- Stop engine.
- Check hoses and tubes between intake manifold and power valve actuator for crack, clogging, improper connection or disconnection. Refer to VACUUM HOSE DRAWING .
OK or NG
- OK: GO TO 5.
- NG: Repair hoses or tubes.
- CHECK VACUUM TANK
Refer to COMPONENT INSPECTION .
OK or NG
- OK: GO TO 6.
- NG: Replace vacuum tank.
- CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect VIAS control solenoid valve harness connector.
- Turn ignition switch ON.
- Check voltage between terminal 1 and ground with CONSULT-II or tester.
- Voltage: Battery voltage
OK or NG
- OK: GO TO 8 .
- NG: GO TO 7.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E5, F14
- IPDM E/R connector E122
- Harness for open or short between VIAS control solenoid valve and IPDM E/R
- Harness for open or short between VIAS control solenoid valve and ECM
- Repair harness or connectors.
- CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 29 and VIAS control solenoid valve terminal 2. Refer to WIRING DIAGRAM
.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 9.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK VIAS CONTROL SOLENOID VALVE
Refer to COMPONENT INSPECTION .
OK or NG
- OK: GO TO 10.
- NG: Replace VIAS control solenoid valve.
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- INSPECTION END