Service Data
Water inlet sub-assembly with thermostat
WATER INLET SUB-ASSEMBLY WITH THERMOSTAT SERVICE DATA
| Standard valve opening temperature | 80to84°C(176to183°F) |
| Standard valve lift | 10.0 mm (0.394 in.) or more at 95°C (203°F) |
Cooling fan motor
COOLING FAN MOTOR SPECIFICATION CHART
| Standard current (No. 1 cooling fan motor) | 13.7to19.7Aat20°C(68°F) |
| Standard current (No. 2 cooling fan motor) | 13.7to19.7Aat20°C(68°F) |
Cooling fan relay
COOLING FAN RELAY CHART
| 3-5 | 10 MΩ or higher |
| 3-5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
Radiator cap sub-assembiy (standard judgment criterion)
RADIATOR CAP SUB-ASSEMBIY SPECIFICATION CHART
| Standard valve (for brand-new cap) | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi) |
|---|---|
| Minimum standard valve (after using cap) | 78.5 kPa (0.8 kgf/cm2 , 11.4 psi) |