Data List / Active Test
- PERFORM ACTIVE TEST
HINT:
Using the intelligent tester or Techstream to perform Active Test allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
- Connect the intelligent tester (with CAN VIM) or Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus.
- Intelligent tester - Select: DIAGNOSIS / OBD/ MOBD / BODY SYSTEM / METER / ACTIVE TEST.
- Techstream - Select: Body Electrical / Combination Meter / Active Test.
- According to the display on tester, perform the "ACTIVE TEST" or "Active Test".
- Intelligent tester
METER:
INTELLIGENT TESTER - METERTester Display Test Part Control Range D-BELT REMIND* Driver side seat belt warning light ON or OFF P-BELT REMIND* Front passenger side seat belt warning light ON or OFF HINT:
*: Confirm that the vehicle is stopped with the engine idling. - Techstream
Combination Meter:
TECHSTREAM - COMBINATION METERTester Display Test Part Control Range D-seat Belt* Driver side seat belt warning light ON or OFF P-seat Belt* Front passenger side seat belt warning light ON or OFF HINT:
*: Confirm that the vehicle is stopped with the engine idling.
- Intelligent tester