LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2007 >> LS 460L >> Repair and Diagnosis >> Steering >> Manual Steering >> Power Steering >> Power Steering System >> Freeze Frame Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Freeze Frame Data

  1. FREEZE FRAME DATA 
    NOTE:
    • It is difficult to show the specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specifications.
    • Turn the engine switch on (IG) and park the vehicle on level ground. Check the freeze frame data by using the intelligent tester or Techstream.
    1. Connect the intelligent tester (with CAN VIM) or Techstream to the DLC3.
    2. Turn the engine switch on (IG) and check the freeze frame data by following the prompts on the intelligent tester's display screen.
      1. Intelligent tester

        EMPS 

        INTELLIGENT TESTER - EMPS

        Tester Display Measurement Item/ Range Normal Condition Diagnostic Note
        ENGINE SPD Vehicle speed from meter/ Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
        1. Vehicle is stopped: 0 km/h (0 mph)
        2. Vehicle is driven at a constant speed: No significant fluctuation
        -
        ENGINE REV Engine revolution/Min.: 0 rpm, Max.: 8,192 rpm Engine is running at a constant speed: No significant fluctuation -
        MOTOR ACTUAL Amount of current to motor/Min.:-128 A, Max.: 127 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in steering system
        COMMAND VALUE Demanded amount of current to motor/Min.:-128 A, Max.: 127 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in steering system
        STR ANGL VEL Steering angle speed/Min.: -4,096 deg/sec, Max.: 4064 deg/sec Steering wheel is turned: Value changes in proportion to steering speed -
        THERMISTOR TEMP ECU substrate temperature/Min.: -50°C, Max.: 205°C Equivalent to ambient ECU substrate temperature -
        IG SUPPLY ECU power source voltage/Min.:0V, Max.: 25.5 V Engine switch on (IG): 11 to 14 V -
        TRQ1 Torque sensor 1 rotation angle/Min.: 0 deg, Max.: 360 deg Steering wheel is turned: Value changes from 0 to 360° every 22.5° of steering angle When malfunction occurs, problem may be in torque sensor
        TRQ2 Torque sensor 2 rotation angle/Min.: 0 deg, Max.: 360 deg Steering wheel is turned: Value changes from 0 to 360° every 22.5° of steering angle When malfunction occurs, problem may be in torque sensor
        TRQ1 ZERO VAL Zero point value of torque sensor 1/Min.: 0 deg, Max.: 360 deg Steering wheel is not turned (without load) When malfunction occurs, problem may be in torque sensor
        TRQ2 ZERO VAL Zero point value of torque sensor 2/Min.: 0 deg, Max.: 360 deg Steering wheel is not turned (without load) When malfunction occurs, problem may be in torque sensor
        STEERING TORQUE Steering torque/Min.: -7.0 N*m, Max.: 7.0 N*m Steering wheel is turned: Value changes in proportion to steering effort When malfunction occurs, problem may be in torque sensor
        MOTOR ROTATE Motor rotation angle/Min.: 0 deg, Max.: 360 deg Steering wheel is turned: Value changes from 0 to 360° every 5° of steering angle When malfunction occurs, problem may be in rotation angle sensor
        COMMAND VALUE 2 Amount of current demanded by motor 2/Min.:-128 A, Max.: 127 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in power steering motor.
        MOTOR VOLTAGE Motor power source voltage/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V -
        MTR TERMINAL (U) Motor terminal voltage (U phase)/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V When malfunction occurs, problem may be in power steering motor.
        MTR TERMINAL (V) Motor terminal voltage (V phase)/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V When malfunction occurs, problem may be in power steering motor.
        MTR TERMINAL (W) Motor terminal voltage (W phase)/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V When malfunction occurs, problem may be in power steering motor.
        BATTERY VOLTAGE Battery voltage/ Min.:0V, Max.: 25.5 V 11 to 14 V -
        DC-DC WARNING 42 V DC / DC converter warning signal/OK or NG OK or NG -
        PS ASSIST SIG Power steering assist signal/ON or OFF ON or OFF -
        MOTOR ACTUAL 2 Amount of current to motor 2/Min.: -327.68 A, Max.: 327.67 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in power steering motor.
      2. Techstream

        EMPS 

        TECHSTREAM - EMPS

        Tester Display Measurement Item/Range Normal Condition Diagnostic Note
        Engine Speed Vehicle speed from meter/Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
        1. Vehicle is stopped: 0 km/h (0 mph)
        2. Vehicle is driven at a constant speed: No significant fluctuation
        -
        Engine Rev Engine revolution/Min.: 0 rpm, Max.: 8,192 rpm Engine is running at a constant speed: No significant fluctuation -
        Motor Actual Amount of current to motor/Min.:-128 A, Max.: 127 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in steering system
        Command Value Demanded amount of current to motor/Min.:-128 A, Max.: 127 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in steering system
        Str Angl Vel Steering angle speed/Min.: -4,096 deg/sec, Max.: 4064 deg/sec Steering wheel is turned: Value changes in proportion to steering speed -
        Thermistor Temp ECU substrate temperature/Min.: -50°C, Max.: 205°C Equivalent to ambient ECU substrate temperature -
        IG Supply ECU power source voltage/Min.: 0 V, Max.: 25.5 V Engine switch on (IG): 11 to 14 V -
        Trq1 Torque sensor 1 rotation angle/Min.: 0 deg, Max.: 360 deg Steering wheel is turned: Value changes from 0 to 360° every 22.5° of steering angle When malfunction occurs, problem may be in torque sensor
        Trq2 Torque sensor 2 rotation angle/Min.: 0 deg, Max.: 360 deg Steering wheel is turned: Value changes from 0 to 360° every 22.5° of steering angle When malfunction occurs, problem may be in torque sensor
        Trq1 Zero Val Zero point value of torque sensor 1/Min.: 0 deg, Max.: 360 deg Steering wheel is not turned (without load) When malfunction occurs, problem may be in torque sensor
        Trq2 Zero Val Zero point value of torque sensor 2/Min.: 0 deg, Max.: 360 deg Steering wheel is not turned (without load) When malfunction occurs, problem may be in torque sensor
        Steering Torque Steering torque/Min.: -7.0 N*m, Max.: 7.0 N*m Steering wheel is turned: Value changes in proportion to steering effort When malfunction occurs, problem may be in torque sensor
        Motor Rotate Motor rotation angle/Min.: 0 deg, Max.: 360 deg Steering wheel is turned: Value changes from 0 to 360° every 5° of steering angle When malfunction occurs, problem may be in rotation angle sensor
        Command Val 2 Amount of current demanded by motor 2/ Min.:-128 A, Max.: 127 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in power steering motor.
        Motor Voltage Motor power source voltage/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V -
        Mtr Terminal(U) Motor terminal voltage (U phase)/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V When malfunction occurs, problem may be in power steering motor.
        Mtr Terminal(V) Motor terminal voltage (V phase)/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V When malfunction occurs, problem may be in power steering motor.
        Mtr Terminal(W) Motor terminal voltage (W phase)/Min.: 0 V, Max.: 64 V Power steering is in operation: 2 to 48 V When malfunction occurs, problem may be in power steering motor.
        Battery Voltage Battery voltage/ Min.: 0 V, Max.: 25.5 V 11 to 14 V -
        DC-DC Warning 42 V DC / DC converter warning signal/OK or NG OK or NG -
        PS Assist Sig Power steering assist signal/ON or OFF ON or OFF -
        Motor Actual 2 Amount of current to motor 2/Min.: -327.68 A, Max.: 327.67 A Power steering is in operation: Value changes in proportion to steering effort When malfunction occurs, problem may be in power steering motor.