Typical Enabling Conditions

All: 

TYPICAL ENABLING CONDITIONS

Monitor runs whenever following DTCs are not present None

After engine stop: 

TYPICAL ENABLING CONDITIONS

Time after engine start 10 seconds or more
Battery voltage 10.5 V or more
ECT sensor circuit OK
ECT change since engine Less than 180°C (356°F)
ECT before engine stop 70°C (158°F)or more
Time that MAF is low before engine stop 70 minutes
Accumulated MAF amount before engine stop 1,893 g (66.8 oz.) or more
Key-off duration 30 minutes

After cold engine start: 

TYPICAL ENABLING CONDITIONS

Key-off duration 5 hours
Time after engine start 10 seconds or more
ECT sensor circuit OK
ECT 70°C (158°F)or more
Accumulated MAF amount 1,893 g (66.8 oz.) or more
Either of the following conditions 1 or 2 is met: -
1. Duration while engine load is low 120 seconds or more
2. Duration while engine load is high 10 seconds or more