Typical Malfunction Thresholds
TYPICAL MALFUNCTION THRESHOLDS
| 1. Frequency that both of following conditions (a) and (b) are met | 5 times or more |
| (a) Engine RPM - Target engine RPM (A/C OFF and NSW OFF) | Less than -100 rpm, or more than 150 rpm |
| (b) Vehicle condition | Stop after vehicle was driven at 10 km/h (6 mph) or more |
| 2. Frequency that both of following conditions (a) and (b) are met | Once |
| (a) Engine RPM - Target engine RPM (A/C OFF and NSW OFF) | Less than -100 rpm, or more than 150 rpm |
| (b) IAC flow rate learning value | 2.48 L/sec or less, or 11 L/sec |