Height Control Accumulator: Disposal
- DISPOSE OF HEIGHT CONTROL ACCUMULATOR ASSEMBLY
- Place the accumulator in a vise and saw a hole between "A" and "B" shown in the illustration using a saw to discharge the gas inside.
CAUTION:- Before the gas discharging, loosen the bleeder plug to bleed high pressure oil.
- The gas discharging is colorless, odorless and harmless.
- Saw a hole while covering the saw with a cloth because chips may fly up.