Monitor Strategy
MONITOR STRATEGY REFERENCE
| Related DTCs | P0705: Park/Neutral position switch/Verify switch input |
| Required sensors/Components | Park/Neutral position switch |
| Frequency of operation | Continuous |
| Duration | Condition (A) and (C) 2 sec. Condition (B) 60 sec. |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |