DTC Summary
DTC TROUBLE DETECTION CONDITION CHART
| DTCs | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
|---|---|---|---|---|---|
| P0441 | Purge VSV (Vacuum Switching Valve) stuck open | Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at start and end of leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM determines that purge VSV is stuck open |
|
While ignition switch OFF | 2 trip |
| P0441 | Purge VSV stuck closed | After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air is introduced into EVAP system. 0.02 inch leak pressure standard is measured at the start and end of leak check. If pressure does not return to near atmospheric pressure, ECM determines that purge valve is stuck closed |
|
While ignition switch OFF | 2 trip |
| P0441 | Purge flow | While engine running, the following conditions are successively met:
|
|
While ignition switch OFF | 2 trip |