Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever this DTC is not present. |
None |
| Ignition switch |
ON |
| Battery voltage |
10.5V or more |
Condition (B) *2
TYPICAL ENABLING CONDITIONS
| One of the following conditions is met |
- |
| NSW switch |
ON |
| P switch |
ON |
| N switch |
ON |
| R switch |
ON |