Typical Malfunction Thresholds
1. One of the following conditions is met: Condition (A), (B) and (C)
Condition (A)
Either of the following conditions (1) or (2) is met:
TYPICAL MALFUNCTION THRESHOLDS
| (1) Number of the following signal input at the same time | 2 or more |
| P switch | ON |
| R switch | ON |
| N switch | ON |
| D switch | ON |
| 3 switch *1 | ON |
| 2 switch *1 | ON |
| (2) Number of the following signal input at the same time | 2 or more |
| NSW switch | ON |
| R switch | ON |
| D switch | ON |
| 3 switch *1 | ON |
| 2 switch *1 | ON |
Condition (B)
TYPICAL MALFUNCTION THRESHOLDS
| M switch (S position switch) *2 | ON |
Condition (C)
Both of the following conditions (1) or (2) is met:
TYPICAL MALFUNCTION THRESHOLDS
| (1) One of the following conditions is met | - |
| NSW switch | ON |
| P switch | ON |
| R switch | ON |
| N switch | ON |
| (2) One of the following conditions is met | - |
| 4 shift position switch | ON |
| L shift position switch | ON |