DTC Summary
DTC DETECTION CONDITION CHART
| DTC No. | Monitoring Item | DTC Detection Condition | Trouble Area | Detection Timing | Detection Logic |
|---|---|---|---|---|---|
| P0441 | EVAP VSV (Vacuum Switching Valve) stuck open | Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at the start and at the end of leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM (Included in HV control ECU) determines that EVAP VSV stuck open |
|
While ignition switch off | 2 trips |
| P0441 | EVAP VSV stuck closed | After EVAP leak check is performed, EVAP VSV turned ON (open), and atmospheric air is introduced into EVAP system. 0.02 inch leak pressure standard is measured at the start and at the end of the check. If pressure does not return to near atmospheric pressure, ECM (Included in HV control ECU) determines that purge valve stuck closed |
|
While ignition switch off | 2 trips |
| P0441 | Purge flow | While engine running, the following conditions are successively met:
|
|
While engine running | 2 trips |