Typical Malfunction Thresholds
Functional check:
TYPICAL MALFUNCTION THRESHOLDS
| Either of following conditions 1 or 2 met | - |
| 1. Frequency that following conditions (a) and (b) met | 5 time or more |
| (a) Engine RPM - target engine RPM | Below -100 rpm, or more than 150 rpm |
| (b) Vehicle condition | Stop after vehicle was driven by 10 km/h (6.25 mph) or more |
| 2. Frequency that following conditions (a) and (b) met | Once |
| (a) Engine RPM - target engine RPM | Below -100 rpm, or 150 rpm or more |