Shift Lever Position Sensor: Inspection
- INSPECT PARK/NEUTRAL POSITION SWITCH
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance
RESISTANCE REFERENCE CHARTA-1 (D) A-2 (N) A-3 (P) A-4 (R) A-5 (MJ) A-6 (FD) A-7 (B) A-9 (RV) P position 10 kΩ or higher 4.2 to 5.1 kΩ Below 1 Ω 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10 kΩ or higher 10 kΩ or higher R position 10 kΩ or higher 4.2 to 5.1 kΩ 10 kΩ or higher Below 1 Ω Below 1 Ω 10 kΩ or higher 10 kΩ or higher Below 1 Ω N position 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10 kΩ or higher 10 kΩ or higher D position Below 1 Ω 4.2 to 5.1 kΩ 10 kΩ or higher 10 kΩ or higher Below 1 Ω Below 1 Ω 10 kΩ or higher B position 10 kΩ or higher 4.2 to 5.1 kΩ 10 kΩ or higher 10 kΩ or higher Below 1 Ω Below 1 Ω Below 1 Ω 10 kΩ or higher