Brake Actuator: Inspection
- INSPECT BRAKE ACTUATOR ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 37 (SMC1) - 36 (BS1) 15.3 to 17.3 Ω 19 (SMC2) - 20 (BS2) 15.3 to 17.3 Ω 44 (SLAFR+) - 43 (SLAFR-) 3.6 to 4.2 Ω 28 (SLRFR+) - 27 (SLRFR-) 3.6 to 4.2 Ω 35 (SLAFL+) - 38 (SLAFL-) 3.6 to 4.2 Ω 21 (SLRFL+) - 22 (SLRFL-) 3.6 to 4.2 Ω 41 (SLARL+) - 42 (SLARL-) 3.6 to 4.2 Ω 25 (SLRRL+) - 26 (SLRRL-) 4.4 to 5.0 Ω 39 (SLARR+) - 40 (SLARR-) 3.6 to 4.2 Ω 23 (SLRRR+) - 24 (SLRRR-) 4.4 to 5.0 Ω 32 (BM2) - 1 (GND1) Below 10 Ω 31 (BM1) - 1 (GND1) Below 10 Ω 32 (BM2) - 31 (BM1) Below 1 Ω 1 (GND1) - 2 (GND2) Below 1 Ω 32 (BM2) - 3 (MTT) About 33 Ω 31 (BM1) - 3 (MTT) About 33 Ω