GS 430
HEATED OXYGEN SENSOR BANK 1 SENSOR 1 HEATER
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $41 |
$90 |
Multiply by 0.001 [A] |
Maximum sensor heater current |
Minimum test |
limit Maximum test limit |
HEATED OXYGEN SENSOR BANK 1 SENSOR 2 HEATER
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $42 |
$90 |
Multiply by 0.001 [A] |
Maximum sensor heater current |
Minimum test limit |
Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 1 HEATER
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $45 |
$90 |
Multiply by 0.001 [A] |
Maximum sensor heater current |
Minimum test limit |
Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 2 HEATER
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $46 |
$90 |
Multiply by 0.001 [A] |
Maximum sensor heater current |
Minimum test limit |
Maximum test limit |
THERMOSTAT
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $E1 |
$E8 |
Multiply by 01 [°C] |
ECT sensor output when estimated ECT reaches to malfunction criteria |
Malfunction criteria |
Maximum test limit |
HEATED OXYGEN SENSOR BANK 1 SENSOR 1 HEATER
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $01 |
$03 |
Multiply by 0.001 [V] |
Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value |
Sensor voltage to define sensor status is Lean |
Sensor voltage to define sensor status is Lean |
| $01 |
$04 |
Multiply by 0.001 [V] |
Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value |
Sensor voltage to define sensor status is Rich |
Sensor voltage to define sensor status is Rich |
| $01 |
$05 |
Multiply by 0.001 [seconds] |
Rich to Lean switch time |
Minimum test limit |
Maximum test limit |
| $01 |
$06 |
Multiply by 0.001 [seconds] |
Lean to Rich switch time |
Minimum test limit |
Maximum test limit |
| $01 |
$07 |
Multiply by 0.005 [V] |
Minimum sensor voltage |
0 V |
Malfunction criterion |
| $01 |
$08 |
Multiply by 0.005 [V] |
Maximum sensor voltage |
Malfunction criterion |
1.0 V |
| $01 |
$81 |
Multiply by 0.001 [seconds] |
Duration while sensor voltage stuck Lean or Rich |
0 |
Malfunction criterion |
| $01 |
$82 |
Multiply by 0.001 [seconds] |
Duration of one sensor frequency |
Minimum test limit |
Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 1 HEATER
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $05 |
$03 |
Multiply by 0.001 [V] |
Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value |
Sensor voltage to define sensor status is Lean |
Sensor voltage to define sensor status is Lean |
| $05 |
$04 |
Multiply by 0.001 [V] |
Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value |
Sensor voltage to define sensor status is Rich |
Sensor voltage to define sensor status is Rich |
| $05 |
$05 |
Multiply by 0.001 [seconds] |
Rich to Lean switch time |
Minimum test limit |
Maximum test limit |
| $05 |
$06 |
Multiply by 0.001 [seconds] |
Lean to Rich switch time |
Minimum test limit |
Maximum test limit |
| $05 |
$07 |
Multiply by 0.005 [V] |
Minimum sensor voltage |
0 V |
Malfunction criterion |
| $05 |
$08 |
Multiply by 0.005 [V] |
Maximum sensor voltage |
Malfunction criterion |
1.0 V |
| $05 |
$81 |
Multiply by 0.001 [seconds] |
Duration while sensor voltage stuck Lean or Rich |
0 |
Malfunction criterion |
| $05 |
$82 |
Multiply by 0.001 [seconds] |
Duration of one sensor frequency |
Minimum test limit |
Maximum test limit |
HEATED OXYGEN SENSOR BANK 1 SENSOR 2
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $02 |
$05 |
Multiply by 0.001 [seconds] |
Rich to Lean switch time |
0 |
Malfunction criterion |
| $02 |
$06 |
Multiply by 0.001 [seconds] |
Lean to Rich switch time |
0 |
Malfunction criterion |
| $02 |
$07 |
Multiply by 0.005 [V] |
Minimum sensor voltage |
Minimum test limit |
Maximum test limit |
| $02 |
$08 |
Multiply by 0.005 [V] |
Maximum sensor voltage |
Minimum test limit |
Maximum test limit |
| $02 |
$84 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sensor voltage was lower than 0.05 V |
0 |
Malfunction criterion |
| $02 |
$85 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sensor voltage was lower than 0.7 V |
Malfunction criterion |
65,535 |
| $02 |
$86 |
Multiply by 0.1 [seconds] |
Duration while sensor voltage was higher than 0.7 V |
0 |
65,535 |
| $02 |
$87 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sensor voltage was higher than 0.45 V |
Minimum test limit |
65,535 |
| $02 |
$88 |
Multiply by 0.1 [seconds] |
Cumulative time that sub-feedback compensation factor remained 7% or more |
0 |
Malfunction criterion |
| $02 |
$89 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sub-feedback compensation factor remained 0.05 V or more |
0 |
Malfunction criterion |
| $02 |
$8A |
Multiply by 1 [time] |
Frequency of sensor switching |
0 |
Malfunction criterion |
| $02 |
$8B |
Multiply by 0.001 [seconds] |
0.35 V to 0.2 V sensor switch time |
0 |
Maximum test limit |
| $02 |
$8D |
Multiply by 0.001 [seconds] |
Duration that sensor voltage dropped to 0.2 V during fuel-cut |
0 |
Malfunction criterion |
| $02 |
$8F |
Multiply by 0.001 [g] |
Maximum oxygen storage capacity |
0 |
Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 2
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $06 |
$05 |
Multiply by 0.001 [seconds] |
Rich to Lean switch time |
0 |
Malfunction criterion |
| $06 |
$06 |
Multiply by 0.001 [seconds] |
Lean to Rich switch time |
0 |
Malfunction criterion |
| $06 |
$07 |
Multiply by 0.005 [V] |
Minimum sensor voltage |
Minimum test limit |
Maximum test limit |
| $06 |
$08 |
Multiply by 0.005 [V] |
Maximum sensor voltage |
Minimum test limit |
Maximum test limit |
| $06 |
$84 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sensor voltage was lower than 0.05 V |
0 |
Malfunction criterion |
| $06 |
$85 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sensor voltage was lower than 0.7 V |
Malfunction criterion |
65,535 |
| $06 |
$86 |
Multiply by 0.1 [seconds] |
Duration while sensor voltage was higher than 0.7 V |
0 |
65,535 |
| $06 |
$87 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sensor voltage was higher than 0.45 V |
Minimum test limit |
65,535 |
| $06 |
$88 |
Multiply by 0.1 [seconds] |
Cumulative time that sub-feedback compensation factor remained 7% or more |
0 |
Malfunction criterion |
| $06 |
$89 |
Multiply by 0.01526 [%] |
Percentage in monitor time when sub-feedback compensation factor remained 0.05 V or more |
0 |
Malfunction criterion |
| $06 |
$8A |
Multiply by 1 [time] |
Frequency of sensor switching |
0 |
Malfunction criterion |
| $06 |
$8B |
Multiply by 0.001 [seconds] |
0.35 V to 0.2 V sensor switch time |
0 |
Maximum test limit |
| $06 |
$8D |
Multiply by 0.001 [seconds] |
Duration that sensor voltage dropped to 0.2 V during fuel-cut |
0 |
Malfunction criterion |
| $06 |
$8F |
Multiply by 0.001 [g] |
Maximum oxygen storage capacity |
0 |
Maximum test limit |
MISFIRE MONITOR - ALL CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A1 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A1 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 1 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A2 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A2 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 2 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A3 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A3 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 3 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A4 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A4 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 4 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A5 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A5 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 5 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A6 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A6 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 6 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A7 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A7 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 7 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A8 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A8 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
MISFIRE MONITOR - 8 CYLINDERS
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $A9 |
$0B |
Multiply by 1 [time] |
Exponential weighted moving average misfire counts for last 10 driving cycles - total |
0 |
65,535 |
| $A9 |
$0C |
Multiply by 1 [time] |
Misfire counts for last and current driving cycles - total |
0 |
65,535 |
CATALYST BANK 1 - USING HEATED OXYGEN SENSOR ON SENSOR 1 AND 2
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $21 |
$A1 |
Multiply by 0.0003 [no dimension] |
Locus length ratio of heated oxygen sensor 1 and 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $21 |
$A2 |
Multiply by 0.0003 [no dimension] |
Voltage area ratio of heated oxygen sensor 1 and sensor 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $21 |
$A3 |
Multiply by 0.0003 [no dimension] |
Locus length ratio of heated oxygen sensor 1 and 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $21 |
$A4 |
Multiply by 0.0003 [no dimension] |
Heated oxygen sensor frequency ratio of sensor 1 and sensor 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $21 |
$A5 |
Multiply by 0.0003 [no dimension] |
Locus length ratio of heated oxygen sensor 1 and 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $21 |
$A6 |
Multiply by 0.0003 [no dimension] |
Voltage area ratio of heated oxygen sensor 1 and sensor 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
CATALYST BANK 2- USING HEATED OXYGEN SENSOR ON SENSOR 1 AND 2
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $22 |
$A1 |
Multiply by 0.0003 [no dimension] |
Locus length ratio of heated oxygen sensor 1 and 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $22 |
$A2 |
Multiply by 0.0003 [no dimension] |
Voltage area ratio of heated oxygen sensor 1 and sensor 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $22 |
$A3 |
Multiply by 0.0003 [no dimension] |
Locus length ratio of heated oxygen sensor 1 and 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $22 |
$A4 |
Multiply by 0.0003 [no dimension] |
Heated oxygen sensor frequency ratio of sensor 1 and sensor 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $22 |
$A5 |
Multiply by 0.0003 [no dimension] |
Locus length ratio of heated oxygen sensor 1 and 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
| $22 |
$A6 |
Multiply by 0.0003 [no dimension] |
Voltage area ratio of heated oxygen sensor 1 and sensor 2 |
Minimum test limit for catalyst |
Maximum test limit for catalyst |
EVAP
| MID |
TID |
Scaling |
Description of Test Value |
Minimum Test Limit |
Maximum Test Limit |
| $3D |
$C9 |
Multiply by 0.01 [kPa] |
Test value for small leak (P0456) Refer to pressure D |
Minimum test limit for small leak |
Maximum test limit for small leak |
| $3D |
$CA |
Multiply by 0.01 [kPa] |
Test value for gross leak (P0455) Refer to pressure E |
Minimum test limit for gross leak |
Maximum test limit for gross leak |
| $3D |
$CB |
Multiply by 0.01 [kPa] |
Test value for vacuum pump stuck OFF (P2401) Refer to pressure A |
Minimum test limit for vacuum pump stuck OFF |
Maximum test limit for vacuum pump stuck OFF |
| $3D |
$CD |
Multiply by 0.01 [kPa] |
Test value for vacuum pump stuck ON (P2402) Refer to pressure A |
Minimum test limit for vacuum pump stuck ON |
Maximum test limit for vacuum pump stuck ON |
| $3D |
$CE |
Multiply by 0.01 [kPa] |
Test value for vent valve stuck OFF (vent) (P2420) Refer to pressure C |
Minimum test limit for vent valve stuck ON |
Maximum test limit for vent valve stuck ON |
| $3D |
$CF |
Multiply by 0.01 [kPa] |
Test value for vent valve stuck ON (P2419) Refer to pressure A |
Minimum test limit for vent valve stuck OFF |
Maximum test limit for vent valve stuck OFF |
| $3D |
$D0 |
Multiply by 0.01 [kPa] |
Test value for 0.02 inch orifice low flow (P043E) Refer to pressure B |
Minimum test limit for 0.02 inch orifice low flow |
Maximum test limit for 0.02 inch orifice low flow |
| $3D |
$D1 |
Multiply by 0.01 [kPa] |
Test value for 0.02 inch orifice high flow (P043F) Refer to pressure A |
Minimum test limit for 0.02 inch orifice high flow |
Maximum test limit for 0.02 inch orifice high flow |
| $3D |
$D4 |
Multiply by 0.01 [kPa] |
Test value for VSV (for EVAP) stuck close (P0441) Refer to pressure F |
Minimum test limit for VSV (for EVAP) stuck close |
Maximum test limit for VSV (for EVAP) stuck close |
| $3D |
$D5 |
Multiply by 0.01 [kPa] |
Test value for VSV (for EVAP) stuck open (P0441) Refer to pressure E |
Minimum test limit for VSV (for EVAP) stuck open |
Maximum test limit for VSV (for EVAP) stuck open |
| $3D |
$D7 |
Multiply by 0.01 [kPa] |
Test value for purge flow (P0441) Refer to pressure G |
Minimum test limit for purge flow |
Maximum test limit for purge flow |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002