Data List / Active Test
WARNING: This page is about a different car, the 2007 Lexus ES 350. However, it is still accessible from the selected car via links, so may be relevant.
HINT:
By accessing the DATA LIST displayed on the intelligent tester, values of switches and sensors can be checked without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method to save diagnostic time.
- DATA LIST FOR OCCUPANT CLASSIFICATION ECU
- Connect the intelligent tester to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus: DIAGNOSIS / OBD/ MOBD / OCCUPANT DETECT / DATA LIST.
- Check the values by referring to the table below.
HINT:
The Specified Condition for Zero Point Calibration in the table below must be satisfied when the zero point calibration is performed.
DATA LIST:
DATA LISTTester Display Measurement Item/ Range Normal Condition Specified Condition for Zero Point Calibration Diagnostic Note PASSENGER CLASS Passenger classification/
NG: Data is not determined
AM50: Adult is seated and seat is in rear position
AF05: Adult is seated and seat is in front position
CHILD: Child is seated
OFF: VacantAM50/AF05/CHILD/OFF OFF - P BUCKLE SW Buckle switch (Passenger side)/
SET: Passenger side seat belt is fastened
UNSET: Passenger side seat belt is unfastened
NG: Data is not determinedUNSET/SET UNSET - RELATIVE PRESS Pressure sensor output/
Min.: 0
Max.: 2550 to 210 0 to 2 - FILTERED PRESS Filtered pressure sensor output/
Min.: 0
Max.: 25538 to 240 38 to 75 If value is outside range of Specified Condition for Zero Point Calibration, check whether any objects placed on seat cushion and that seat cushion fitted correctly. THERMISTOR TEMP Thermistor temperature output/
Min.: -40°C (40°F)
Max.: 90°C (194°F)-40° to 85°C (-40° to 185°F) 3° to 40°C (36° to 104°F) If value is outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc. WEIGHT THRESH Weight threshold/
Min.: 0
Max.: 25536 to 67 (reference value) 36 to 67 (reference value) - FILTERED TENSION Filtered belt tension output/
Min.: 0
Max.: 25539 to 229 39 to 64 (no load) - EMPTY THRESH Empty threshold value from seat factory/
Min.: 0
Max.: 25538 to 75 38 to 75 - ALLOW THRESH Threshold value for adult passenger or not from seat factory/
Min.: 0
Max.: 25543 to 64 (reference value) 43 to 64 (reference value) - #PRESENT CODES Number of present trouble codes/
Min.: 0
Max.: 2550 0 - #PAST CODES Number of past trouble codes/
Min.: 0