Inspection Procedure
- CHECK POWER DOOR LOCK OPERATION
- When the master switch assembly's door control switch is operated, check that the locked doors unlock.
Result
RESULT REFERENCEResult Proceed to Door locks operate normally OK Door locks do not operate normally NG
NG: GO TO POWER DOOR LOCK CONTROL SYSTEM
OK: Go to next step
- When the master switch assembly's door control switch is operated, check that the locked doors unlock.
- READ VALUE OF TECHSTREAM (OUTSIDE HANDLE)
- Using the Techstream, read the Data List.
Driver Door (Front door ECU LH)
MEASUREMENT ITEM/DISPLAY CHARTTester Display Measurement Item/Display Normal Condition Diagnostic Note Outside Handle Trigger SW Driver side door outside handle lock switch / ON or OFF ON: Driver side door outside handle lock switch is pushed
OFF: Driver side door outside handle lock switch is not pushed- OK: On the screen, item changes between ON and OFF according to above chart.
NG: Go to step 4
OK: Go to next step
- Using the Techstream, read the Data List.
- CHECK FRONT DOOR ECU LH (OPERATION)
- Replace the front door ECU LH with a new one or normally functioning one (see INSTALLATION ).
- Check that the entry function operates normally.
OK: Operates normally
NG: REPLACE CERTIFICATION ECU
OK: END (FRONT DOOR ECU LH IS DEFECTIVE)
- INSPECT FRONT DOOR OUTSIDE HANDLE LH
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCETester Connection Switch Condition Specified Condition b2-3 (TRG+) - b2-1 (TRG-) ON Below 1 Ω b2-3 (TRG+) - b2-1 (TRG-) OFF 10 kΩ or higher
NG: REPLACE FRONT DOOR OUTSIDE HANDLE LH (See INSTALLATION )
OK: Go to next step
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (FRONT DOOR OUTSIDE HANDLE LH - FRONT DOOR ECU LH)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the b2 handle connector.
- Disconnect the N10 ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCETester Connection Condition Specified Condition b2-3 (TRG+) - N10-20 (TRG+) Always Below 1 Ω b2-3 (TRG+) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (FRONT DOOR OUTSIDE HANDLE LH - DOOR ELECTRICAL KEY OSCILLATOR)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the b2 handle connector.
- Disconnect the b1 oscillator connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCETester Connection Condition Specified Condition b2-1 (TRG-) - b1-9 (TRG-) Always Below 1 Ω b2-1 (TRG-) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK DOOR ELECTRICAL KEY OSCILLATOR (OPERATION)
- Replace the door electrical key oscillator with a new one or normally functioning one (see INSTALLATION ).
- Check that the entry function operates normally.
OK: Operates normally
NG: Go to step 8
OK: END (DOOR ELECTRICAL OSCILLATOR IS DEFECTIVE)
- CHECK FRONT DOOR ECU LH (OPERATION)
- Replace the front door ECU LH with a new one or normally functioning one (see INSTALLATION ).
- Check that the entry function operates normally.
OK: Operates normally
NG: REPLACE CERTIFICATION ECU
OK: END (FRONT DOOR ECU LH IS DEFECTIVE)