Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0110: Intake air temperature sensor open/short (Fluctuating) P0112: Intake air temperature sensor short (Low electrical voltage) P0113: Intake air temperature sensor open (High electrical voltage) |
| Required Sensors / Components (Main) | Intake Air Temperature (IAT) sensor |
| Required sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |