Typical Enabling Conditions
| Monitor will run whenever these DTCs are not present | P0115, P0117, P0118 (Engine Coolant Temperature Sensor) |
COLD START MONITOR:
| Battery voltage | 10.5 V or more |
| Time after engine start | 1 second or more |
| ECT at engine start | Less than 60°C (140°F) |
| Soak time | 0 seconds or more |
| Accumulated MAF | 2040 g or more |
| Fuel cut | OFF |
| Difference between ECT at engine start and IAT | Less than 40°C (72°F) |
SOAK MONITOR:
| Battery voltage | 10.5 V or more |
| Engine | Running |
| Soak time | 5 hours or more |
| ECT at engine start | 60°C (140°F) or more |
| Accumulated MAF | 4161 g or more |