Customize Parameters
- CUSTOMIZE PARAMETERS NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Customize Setting /
- Select the setting by referring to the table below.
Warning
SETTING REFERENCE CHARTDisplay Default Contents Setting Fr Sensor Onset Range Wide Function to set buzzer activation range (for front sensors) Narrow or Wide Rr Sensor Onset Range Wide Function to set buzzer activation range (for rear sensors) Narrow or Wide Keep Sense Buzzer Avail Function to make buzzer sound when distance between vehicle and obstacle does not change for more than 3 seconds Not Avail or Avail Fr & Rr Buzzer Freq Middle Buzzer sounding frequency Low, Middle or High Fr & Rr Buzzer Volume M2 Buzzer volume setting L, M1, M2, M3 or H Sensor
SENSOR SETTING REFERENCE CHARTDisplay Default Contents Setting Sensor Condition N Avail Function to make sensors available when shift position is N Not Avail or Avail Front Side Dist Sensor Long Function to set buzzer activation range (for front sensors) Short or Long Reverse Range Front Sensor Fsde Operation setting for vehicle front sensors (front center, front corner, front side) when shift lever is in R position F, Fs, Fc, Fsde or F Stop Non P/R Range Rear Sensor R Stop Operation setting for vehicle rear sensors (rear center, rear corner) when shift lever is in position other than P or R R, Rcrn or R Stop Display
DISPLAY SETTING REFERENCE CHARTDisplay Default Contents Setting Approach Display OFF Avail Display when moving away from previously detected obstacle Not Avail or Avail Display Mode All Display mode setting (when intuitive parking assist system is normal) All or Undisp