LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2009 >> LS 460L AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 295 (Electric Power Control System (Diagnostic Codes)) >> Electric Power Control System >> DTC B22AE: Open in Alternater Charge Line >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC B22AE: Open in Alternater Charge Line: Procedure

WARNING: This page is about a different car, the 2010 Lexus LS 460L and 2010 Lexus LS 460. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK GENERATOR ASSEMBLY (TERMINAL B) 
    1. Check the generator's tightening torque value.

      Standard torque

      Generator Standard torque
      Terminal 1 (B) 12 N*m (122 kgf*cm, 8.82 ft.*lbf)

    NG → TIGHTEN GENERATOR ASSEMBLY (TERMINAL B) 

    OK: Go to next step 

  2. CHECK GENERATOR ASSEMBLY (IG INPUT VOLTAGE) 
    Fig 1: Identifying E24 Generator Connector Terminals
    GTY288828Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the E24 generator connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard voltage

      Tester Connection Switch Condition Specified Condition
      E24-2 (IG) - Body ground Engine switch on (IG) 11 to 14 V

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → REPLACE PASSENGER SIDE JUNCTION BLOCK (ELECTRIC POWER CONTROL ECU)