Typical Enabling Conditions

WARNING: This page is about a different variant/trim than selected.

All 

TYPICAL ENABLING CONDITIONS CHART

The monitor will run whenever the following DTCs are not stored P0115, P0117, P0118: ECT (Engine coolant temperature) sensor circuit
P0120, P0122, P0123, P0220, P0222, P0223, P2102, P2103, P2118, P2135: ETCS (Electronic throttle control system)
P0327, P0328, P032C, P032D, P0332, P0333, P033C, P033D: KCS sensor circuit
P0502, P0503: Output speed sensor circuit
P0712, P0713: ATF temperature sensor circuit
P0715, P0717: Turbine speed sensor circuit
P0748: Shift solenoid valve SL1 circuit
P0778: Shift solenoid valve SL2 circuit
P0798: Shift solenoid valve SL3 circuit
P0985, P0986: Shift solenoid valve SR circuit
P2810: Shift solenoid valve SL4 circuit
P2819: Shift solenoid valve SL5 circuit
U0100: CAN communication circuit (ECM - TCM)
NSW switch "D"
Duration time from shifting "N" to "D" 4 sec. or more
ATF temperature -10°C (14°F) or higher
Engine Running

OFF malfunction (A) 

TYPICAL ENABLING CONDITIONS CHART

TCM indicated pressure value of SL1 1600 kPa (16.3 kgf/cm2 , 232 psi)

OFF malfunction (B) 

TYPICAL ENABLING CONDITIONS CHART

TCM selected gear 1st
Duration time from vehicle speed reaching the following value Less than 3 sec.
Vehicle speed 2 km/h (1.24 mph) or more and less than 40 km/h (24.86 mph)
Engine speed - Turbine speed 150 RPM or more
Calculated load value 7.75% or more
ECT (Engine Coolant Temperature) 40°C (104°F) or higher
Spark advance from max. retard timing by KCS control Crankshaft angle 0° or more

When either condition below is met: Condition (1) or (2)

Condition (1) 

When one of the following conditions is met: Condition (a), (b), (c), (d), (e), (f), (g) or (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 1st gear) More than 3.9 and 8.0 or less (when output speed less than 130 RPM)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 2nd gear) More than 2.4 and 2.9 or less (when output speed less than 200 RPM)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 3rd gear) More than 1.72 and 2.07 or less (when output speed less than 400 RPM)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 4th gear) More than 1.354 and 1.584 or less (when output speed less than 600 RPM)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 5th gear) More than 1.141 and 1.291 or less (when output speed less than 600 RPM)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 6th gear) More than 0.93 and 1.07 or less (when output speed less than 800 RPM)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 7th gear) More than 0.759 and 0.889 or less (when output speed less than 800 RPM)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 8th gear) More than 0.62 and 0.75 or less (when output speed less than 1000 RPM)

Condition (2) 

When all conditions below are met: Condition (a), (b), (c), (d), (e), (f), (g) and (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 1st gear ratio (Actual 1st gear) More than -50 RPM and 50 RPM or less (when output speed 130 RPM or more)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 2nd gear ratio (Actual 2nd gear) More than -50 RPM and 50 RPM or less (when output speed 200 RPM or more)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 3rd gear ratio (Actual 3rd gear) More than -50 RPM and 50 RPM or less (when output speed 400 RPM or more)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 4th gear ratio (Actual 4th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 5th gear ratio (Actual 5th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 6th gear ratio (Actual 6th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 7th gear ratio (Actual 7th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 8th gear ratio (Actual 8th gear) More than -50 RPM and 50 RPM or less (when output speed 1000 RPM or more)

OFF malfunction (C) 

TYPICAL ENABLING CONDITIONS CHART

TCM selected gear 2nd
Vehicle speed 2 km/h (1.24 mph) or more
Throttle valve opening amount 6.5% or more at engine speed 2000 RPM (condition varies with engine speed)
Calculated load value 7.75% or more
ECT (Engine Coolant Temperature) 40°C (104°F) or higher
Spark advance from max. retard timing by KCS control Crankshaft angle 0° or more

When either condition below is met: Condition (1) or (2)

Condition (1) 

When one of the following conditions is met: Condition (a), (b), (c), (d), (e), (f), (g) or (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 1st gear) More than 3.9 and 8.0 or less (when output speed less than 130 RPM)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 2nd gear) More than 2.4 and 2.9 or less (when output speed less than 200 RPM)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 3rd gear) More than 1.72 and 2.07 or less (when output speed less than 400 RPM)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 4th gear) More than 1.354 and 1.584 or less (when output speed less than 600 RPM)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 5th gear) More than 1.141 and 1.291 or less (when output speed less than 600 RPM)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 6th gear) More than 0.93 and 1.07 or less (when output speed less than 800 RPM)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 7th gear) More than 0.759 and 0.889 or less (when output speed less than 800 RPM)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 8th gear) More than 0.62 and 0.75 or less (when output speed less than 1000 RPM)

Condition (2) 

When all conditions below are met: Condition (a), (b), (c), (d), (e), (f), (g) and (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 1st gear ratio (Actual 1st gear) More than -50 RPM and 50 RPM or less (when output speed 130 RPM or more)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 2nd gear ratio (Actual 2nd gear) More than -50 RPM and 50 RPM or less (when output speed 200 RPM or more)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 3rd gear ratio (Actual 3rd gear) More than -50 RPM and 50 RPM or less (when output speed 400 RPM or more)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 4th gear ratio (Actual 4th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 5th gear ratio (Actual 5th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 6th gear ratio (Actual 6th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 7th gear ratio (Actual 7th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 8th gear ratio (Actual 8th gear) More than -50 RPM and 50 RPM or less (when output speed 1000 RPM or more)

OFF malfunction (D) 

TYPICAL ENABLING CONDITIONS CHART

TCM selected gear 3rd
Vehicle speed 2 km/h (1.24 mph) or more
Throttle valve opening amount 6.5% or more at engine speed 2000 RPM (condition varies with engine speed)
Calculated load value 7.75% or more
ECT (Engine Coolant Temperature) 40°C (104°F) or higher
Spark advance from max. retard timing by KCS control Crankshaft angle 0° or more

When either condition below is met: Condition (1) or (2)

Condition (1) 

When one of the following conditions is met: Condition (a), (b), (c), (d), (e), (f), (g) or (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 1st gear) More than 3.9 and 8.0 or less (when output speed less than 130 RPM)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 2nd gear) More than 2.4 and 2.9 or less (when output speed less than 200 RPM)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 3rd gear) More than 1.72 and 2.07 or less (when output speed less than 400 RPM)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 4th gear) More than 1.354 and 1.584 or less (when output speed less than 600 RPM)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 5th gear) More than 1.141 and 1.291 or less (when output speed less than 600 RPM)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 6th gear) More than 0.93 and 1.07 or less (when output speed less than 800 RPM)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 7th gear) More than 0.759 and 0.889 or less (when output speed less than 800 RPM)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 8th gear) More than 0.62 and 0.75 or less (when output speed less than 1000 RPM)

Condition (2) 

When ail conditions below are met: Condition (a), (b), (c), (d), (e), (f), (g) and (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 1st gear ratio (Actual 1st gear) More than -50 RPM and 50 RPM or less (when output speed 130 RPM or more)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 2nd gear ratio (Actual 2nd gear) More than -50 RPM and 50 RPM or less (when output speed 200 RPM or more)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 3rd gear ratio (Actual 3rd gear) More than -50 RPM and 50 RPM or less (when output speed 400 RPM or more)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 4th gear ratio (Actual 4th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 5th gear ratio (Actual 5th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 6th gear ratio (Actual 6th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 7th gear ratio (Actual 7th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 8th gear ratio (Actual 8th gear) More than -50 RPM and 50 RPM or less (when output speed 1000 RPM or more)

OFF malfunction (E) 

TYPICAL ENABLING CONDITIONS CHART

TCM selected gear 4th
Vehicle speed 2 km/h (1.24 mph) or more
Throttle valve opening amount 6.5% or more at engine speed 2000 RPM (condition varies with engine speed)
Calculated load value 7.75% or more
ECT (Engine Coolant Temperature) 40°C (104°F) or higher
Spark advance from max. retard timing by KCS control Crankshaft angle 0° or more

When either condition below is met: Condition (1) or (2)

Condition (1) 

When one of the following conditions is met: Condition (a), (b), (c), (d), (e), (f), (g) or (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 1st gear) More than 3.9 and 8.0 or less (when output speed less than 130 RPM)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 2nd gear) More than 2.4 and 2.9 or less (when output speed less than 200 RPM)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 3rd gear) More than 1.72 and 2.07 or less (when output speed less than 400 RPM)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 4th gear) More than 1.354 and 1.584 or less (when output speed less than 600 RPM)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 5th gear) More than 1.141 and 1.291 or less (when output speed less than 600 RPM)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 6th gear) More than 0.93 and 1.07 or less (when output speed less than 800 RPM)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 7th gear) More than 0.759 and 0.889 or less (when output speed less than 800 RPM)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 8th gear) More than 0.62 and 0.75 or less (when output speed less than 1000 RPM)

Condition (2) 

When all conditions below are met: Condition (a), (b), (c), (d), (e), (f), (g) and (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 1st gear ratio (Actual 1st gear) More than -50 RPM and 50 RPM or less (when output speed 130 RPM or more)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 2nd gear ratio (Actual 2nd gear) More than -50 RPM and 50 RPM or less (when output speed 200 RPM or more)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 3rd gear ratio (Actual 3rd gear) More than -50 RPM and 50 RPM or less (when output speed 400 RPM or more)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 4th gear ratio (Actual 4th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 5th gear ratio (Actual 5th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 6th gear ratio (Actual 6th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 7th gear ratio (Actual 7th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 8th gear ratio (Actual 8th gear) More than -50 RPM and 50 RPM or less (when output speed 1000 RPM or more)

OFF malfunction (F) 

TYPICAL ENABLING CONDITIONS CHART

TCM selected gear 5th
Vehicle speed 2 km/h (1.24 mph) or more
Throttle valve opening amount 6.5% or more at engine speed 2000 RPM (condition varies with engine speed)
Calculated load value 7.75% or more
ECT (Engine Coolant Temperature) 40°C (104°F) or higher
Spark advance from max. retard timing by KCS control Crankshaft angle 0° or more

When either condition below is met: Condition (1) or (2)

Condition (1) 

When one of the following conditions is met: Condition (a), (b), (c), (d), (e), (f), (g) or (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 1st gear) More than 3.9 and 8.0 or less (when output speed less than 130 RPM)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 2nd gear) More than 2.4 and 2.9 or less (when output speed less than 200 RPM)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 3rd gear) More than 1.72 and 2.07 or less (when output speed less than 400 RPM)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 4th gear) More than 1.354 and 1.584 or less (when output speed less than 600 RPM)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 5th gear) More than 1.141 and 1.291 or less (when output speed less than 600 RPM)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 6th gear) More than 0.93 and 1.07 or less (when output speed less than 800 RPM)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 7th gear) More than 0.759 and 0.889 or less (when output speed less than 800 RPM)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed/Output speed (NT/NO) (Actual 8th gear) More than 0.62 and 0.75 or less (when output speed less than 1000 RPM)

Condition (2) 

When all conditions below are met: Condition (a), (b), (c), (d), (e), (f), (g) and (h)

Condition (a) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 1st gear ratio (Actual 1st gear) More than -50 RPM and 50 RPM or less (when output speed 130 RPM or more)

Condition (b) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 2nd gear ratio (Actual 2nd gear) More than -50 RPM and 50 RPM or less (when output speed 200 RPM or more)

Condition (c) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 3rd gear ratio (Actual 3rd gear) More than -50 RPM and 50 RPM or less (when output speed 400 RPM or more)

Condition (d) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 4th gear ratio (Actual 4th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (e) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 5th gear ratio (Actual 5th gear) More than -50 RPM and 50 RPM or less (when output speed 600 RPM or more)

Condition (f) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 6th gear ratio (Actual 6th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (g) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 7th gear ratio (Actual 7th gear) More than -50 RPM and 50 RPM or less (when output speed 800 RPM or more)

Condition (h) 

TYPICAL ENABLING CONDITIONS CHART

Turbine speed - Output speed (NT - NO) x 8th gear ratio (Actual 8th gear) More than -50 RPM and 50 RPM or less (when output speed 1000 RPM or more)