Data List / Active Test
HINT:
By accessing the DATA LIST displayed on Techstream, values of switches and sensors can be checked without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method to save diagnostic time.
- DATA LIST FOR OCCUPANT CLASSIFICATION ECU
- Turn the engine switch off.
- Connect Techstream to the DLC3.
- Turn the engine switch on (IG) and turn the tester on.
- Enter the following menus: Body Electrical / Occupant Detection / Data List.
- Check the values by referring to the table below.
HINT:
The Specified Condition for Zero Point Calibration in the table below must be satisfied when the zero point calibration is performed.
DATA LIST:Tester Display Measurement Item/Range Normal Condition Specified Condition for Zero Point Calibration Diagnostic Note Passenger Classification Passenger classification/
NG: Data is not determined
AM50: Adult is seated and seat is in rear position
AF05: Adult is seated and seat is in front position
CHILD: Child is seated
OFF: VacantAM50/AF05/CHILD/OFF OFF - Passenger Buckle SW Buckle switch (Passenger side)/
Set: Passenger side seat belt is fastened
Unset: Passenger side seat belt is unfastened
NG: Data is not determinedUnset/Set Unset - Pressure sensor output Pressure sensor output/
Min.: 0
Max.: 2550 to 210 0 to 2 - Filtered pressure sensor output Filtered pressure sensor output/
Min.: 0
Max.: 25538 to 240 38 to 75 If value is outside range of Specified Condition for Zero Point Calibration, check whether any objects placed on seat cushion and that seat cushion fitted correctly. Thermistor temperature output Thermistor temperature output/
Min.: -40°C (-40°F)
Max.: 90°C (194°F)-40° to 85°C (-40° to185°F) 3° to 40°C (36° to 104°F) If value is outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc. Weight threshold Weight threshold/
Min.: 0
Max.: 25536 to 67
(reference value)36 to 67
(reference value)- Filtered belt tension output Filtered belt tension output/
Min.: 0
Max.: 25539 to 229 39 to 64
(no load)- Empty threshold value from the seat factory Empty threshold value from seat factory/
Min.: 0
Max.: 25538 to 75 38 to 75 - Allow threshold Threshold value for adult passenger or not from seat factory/
Min.: 0
Max.: 25543 to 64
(reference value)43 to 64
(reference value)- Number of Present DTC Number of present trouble codes/
Min.: 0
Max.: 2550 0 - Number of Past DTC Number of past trouble codes/
Min.: 0
Max.: 2550 0 -