LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2010 >> GX 460 >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging (Service Specifications) >> 1UR-FE Battery / Charging >> Service Data >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

Battery Standard specific gravity 1.25 to 1.29 at 20 °C (68 °F)
Charging circuit without load Standard current 10 A or less
Standard voltage 13.2 to 14.8 V
(when engine speed at 2000 RPM)
Charging circuit with load Standard current 30 A or higher
Generator rotor Standard resistance between the slip rings 130 A Type 2.3 to 2.7 Ω at 20 °C (68 °F)
150 A Type 1.5 to 1.9 Ω at 20 °C (68 °F)
Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter 14.0 mm (0.551 in.)
Generator brush holder Standard exposed length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length 4.5 mm (0.177 in.)