Pattern Select Switch Eco Mode Circuit: Procedure
- READ VALUE USING TECHSTREAM (CAN BUS CHECK) See step 2
B → See step 12
A: Go to next step
- CHECK DTC OUTPUT (HEALTH CHECK) See step 3
B → GO TO DTC CHART
A: Go to next step
- PERFORM ACTIVE TEST USING TECHSTREAM (INDICAT. ECO MODE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Body Electrical / Combination Meter / Active Test / Indicat. ECO Mode.
- Perform the "Indicat. ECO MODE" Active Test.
OK
The ECO MODE indicator lamp comes on or blinks.
- Turn the power switch off.
NG → See step 13
OK: Go to next step
- READ VALUE USING TECHSTREAM (ECO MODE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Data List / ECO Mode.
- Read the value displayed on the Techstream.
Tester Display Measurement Item/Range Normal Condition ECO Mode ECO mode transition availability/
ON or OFFIn ECO mode: ON Result
Result Proceed to The Techstream display changes according to the mode switch (ECO mode) operation. A The Techstream display does not changes according to the mode switch (ECO mode) operation. B
B → See step 5
A → See step 11
- READ VALUE USING TECHSTREAM (ECO SWITCH)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Body Electrical / Air Conditioning / Data List / ECO Switch.
- Read the value displayed on the Techstream.
Tester Display Measurement Item/Range Normal Condition ECO Switch Mode switch (ECO mode) condition/
ON or OFFMode switch being turned and held at ECO position: ON
Mode switch not turned: OFFResult
Result Proceed to The Techstream display changes according to the mode switch (ECO mode) operation. A The Techstream display does not changes according to the mode switch (ECO mode) operation. B
B → See step 6
A → See step 14
- CHECK COMBINATION SWITCH ASSEMBLY (ECO MODE / NORMAL MODE)
- Remove the combination switch assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H72-5 (ECO) - H72-13 (E) Mode switch being turned and held at ECO position Below 1 Ω Mode switch not turned 10 kΩ or higher H72-4 (NORM) - H72-14 (E) Mode switch being pushed and held Below 1 Ω Mode switch not pushed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Combination Switch Assembly) - Install the combination switch assembly.
NG → See step 10
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COMBINATION SWITCH)
- Disconnect connector H85 from the air conditioning amplifier assembly.
- Disconnect connector H72 from the combination switch assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H85-15 (ECON) - H72-5 (ECO) Always Below 1 Ω H85-15 (ECON) or H72-5 (ECO) - Body ground Always 10 kΩ or higher H85-35 (SG-4) - H72-13 (E) Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)*b Front view of wire harness connector
(to Combination Switch Assembly) - Connect the combination switch assembly connector.
- Connect the air conditioning amplifier assembly connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - BODY GROUND) See step 7
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (ECM - COMBINATION SWITCH ASSEMBLY)
- Disconnect connector A60 from the ECM.
- Disconnect connector H72 from the combination switch assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A60-30 (NE01) - H72-4 (NORM) Always Below 1 Ω A60-30 (NE01) or H72-4 (NORM) - Body ground Always 10 kΩ or higher TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to ECM)*b Front view of wire harness connector
(to Combination Switch Assembly) - Connect the combination switch assembly connector.
- Connect the ECM connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 14
- REPLACE COMBINATION SWITCH ASSEMBLY. Refer to COMPONENTS
- CHECK FOR INTERMITTENT PROBLEMS. Refer to CHECK FOR INTERMITTENT PROBLEMS
- GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING
- REPLACE COMBINATION METER ASSEMBLY. Refer to COMPONENTS
- REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to COMPONENTS