Typical Enabling Conditions
ALL:
| Monitor runs whenever following DTCs are not present | None |
AFTER ENGINE STOP:
| Time after engine start | 10 seconds or more |
| Battery voltage | 10.5 V or more |
| IAT sensor circuit fail (P0112, P0113) | Not detected |
| ECT sensor circuit fail (P0115, P0117, P0118) | Not detected |
| MAF sensor circuit fail (P0102, P0103) | Not detected |
| Accumulated mass air flow amount in previous driving cycle | 3013 g or more |
| ECT before engine stop | -40°C (-40°F) or more |
| Key-off duration | 30 minutes |
AFTER COLD ENGINE START:
| Key-off duration | 5 hours or more |
| Time after engine start | 10 seconds or more |
| IAT sensor circuit fail (P0112, P0113) | Not detected |
| ECT sensor circuit fail (P0115, P0117, P0118) | Not detected |
| MAF sensor circuit fail (P0102, P0103) | Not detected |
| Accumulated MAF amount | 3013 g or more |
| One of the following conditions 1 or 2 is met: | - |
| 1. Duration while engine load is low | 120 seconds or more |
| 2. Duration while engine load is high | 10 seconds or more |