Typical Enabling Conditions
ALL
| Monitor runs whenever following DTCs are not present | None |
AFTER ENGINE STOP
| Time after engine start | 10 seconds or more |
| Battery voltage | 10.5 V or more |
| IAT sensor circuit (P0112, P0113) | OK |
| ECT sensor circuit (P0115, P0117, P0118) | OK |
| MAF sensor circuit (P0102, P0103) | OK |
| Accumulated mass air flow amount in previous driving cycle | 3768 g or more |
| ECT when 30 minutes elapsed after engine stop | -40°C (-40°F) or more |
AFTER COLD ENGINE START
| Key-off duration | 5 hours or more |
| Time after engine start | 10 seconds or more |
| IAT sensor circuit (P0112, P0113) | OK |
| ECT sensor circuit (P0115, P0117, P0118) | OK |
| MAF sensor circuit (P0102, P0103) | OK |
| Accumulated MAF amount | 3768 g or more |
| Either of the following conditions is met: | Condition a or b |
| a. Duration while engine load is low | 120 second or more |
| b. Duration while engine load is high | 10 seconds or more |