Data List/Active Test
WARNING: This page is about a different car, the 2011 Lexus IS 350 and 2011 Lexus IS 250. However, it is still accessible from the selected car via links, so may be relevant.
- DATA LIST FOR OCCUPANT CLASSIFICATION ECU
HINT:
Using the Techstream to read the DATA LIST allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the DATA LIST information early in troubleshooting is one way to save diagnostic time.
NOTE:In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
- Warm up the engine.
- Turn the engine switch off.
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical/Occupant Detection/Data List.
- According to the display on Techstream, read the "DATA LIST".OCCUPANT CLASSIFICATION ECU:
Tester Display Measurement Item/Range Normal Condition Specified Condition for Zero Point Calibration Diagnostic Note Passenger Classification Passenger classification/NG, AM50, AF05, CHILD or OFF NG: Data is not determined
AM50: Adult is seated and seat is in rear position
AF05: Adult is seated and seat is in front position
CHILD: Child is seated
OFF: VacantOFF - Passenger Buckle SW Buckle switch (passenger side)/Set, Unset or NG Set: Passenger side seat belt is fastened
Unset: Passenger side seat belt is unfastened
NG: Data is not determinedUnset - Pressure sensor output Pressure sensor output/Min.:0, Max.: 255 0 to 210
(reference value)0 to 2 - Filtered pressure sensor output Filtered pressure sensor output/Min.: 0, Max.: 255 38 to 240 38 to 75 If value is outside range of Specified Condition for Zero Point Calibration, check whether any objects placed on seat cushion and that seat cushion fitted correctly Thermistor temperature output Thermistor temperature output/Min.: -40°C (-40°F), Max.: 90°C (194°F) -40 to 85°C
(-40 to 185°F)3 to 40°C
(36 to 104°F)If value is outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc. Weight threshold Weight threshold/Min.: 0, Max.: 255 36 to 67
(reference value)36 to 67
(reference value)- Filtered belt tension output Filtered belt tension output/Min.: 0, Max.: 255 39 to 229 39 to 64
(no load)- Empty threshold value from the seat factory Empty threshold value from seat factory/Min.: 0, Max.: 255 38 to 75 38 to 75 - Allow threshold Threshold value for adult passenger or not from seat factory/Min.: 0, Max.: 255 43 to 64
(reference value)43 to 64
(reference value)- Number of Present DTC Number of present trouble codes/Min.: 0, Max.: 255 0 0 - Number of Past DTC Number of past trouble codes/Min.: 0, Max.: 255 0 0 -