Service Data
| SMRB (HV battery junction block assembly) Resistance |
g2-1 (CBI) - z30-1 (+) | 10 kΩ or higher (Battery voltage is not applied between terminals z38-3 [SMRB] and z38-2 [GND]) |
| g2-1 (CBI) - z30-1 (+) | Below 1Ω (Battery voltage is applied between terminals z38-3 [SMRB] and z38-2 [GND]) |
|
| g2-1 (CBI) - z58-1 (CBD) | Below 1Ω (Always) |
|
| g2-1 (CBI) - z27-1 (CBPE) | Below 1Ω (Always) |
|
| z38-3 (SMRB) - z38-2 (GND) | 18.8 to 32.1 Ω at -35 to 80°C (-31 to 176°F) | |
| SMRG (HV battery junction block assembly) Resistance |
g3-1 (CEI) - z34-1 (-) | 10 kΩ or higher (Battery voltage is not applied between terminals z38-1 [SMRG] and z38-2 [GND]) |
| g3-1 (CEI) - z34-1 (-) | Below 1Ω (Battery voltage is applied between terminals z38-1 [SMRG] and z38-2 [GND]) |
|
| g3-1 (CEI) - z59-1 (CED) | Below 1Ω (Always) |
|
| z34-1 (-) - z60-1 (INR) | Below 1Ω (Always) |
|
| g3-1 (CEI) - z27-4 (CEPE) | Below 1Ω (Always) |
|
| z38-1 (SMRG) - z38-2 (GND) | 18.8 to 32.1 Ω at -35 to 80°C (-31 to 176°F) | |
| luggage room junction block (Battery blower relay) Resistance (BATT FAN1) |
LG-1 - LD-3 | 10 kΩ or higher (Battery voltage is not applied between terminals LH-1 and LD-14) |
| LG-1 - LD-3 | Below 1Ω (Battery voltage is applied between terminals LH-1 and LD-14) |
|
| luggage room junction block (Battery blower relay) Resistance (BATT FAN2) |
LG-1 - LA-41 | 10 kΩ or higher (Battery voltage is not applied between terminals LH-1 and LD-14) |
| LG-1 - LA-41 | Below 1Ω (Battery voltage is applied between terminals LH-1 and LD-14) |