LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2012 >> CT 200h Base >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (Diagnostic Codes & Symptom Tests) >> Power Window Control System >> Symptom Tests >> Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch: Procedure

  1. READ VALUE USING TECHSTREAM (Master Switch) 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Master switch / Data List.
    5. Read the Data List according to the display on the Techstream.
      MASTER SWITCH (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY)

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      D Door P/W Auto SW Driver door power window auto up and down switch signal / ON or OFF ON: Driver door power window auto switch operated
      OFF: Driver door power window auto switch not operated
      -

      OK

      On the Techstream screen, ON or OFF is displayed accordingly.

    NG → See step   7 

    OK: Go to next step 

  2. READ VALUE USING TECHSTREAM (D-Door Motor) 
    1. Enter the following menus: Body Electrical / D-Door Motor / Data List.
    2. Read the Data List according to the display on the Techstream.
      D-DOOR MOTOR (POWER WINDOW REGULATOR MOTOR ASSEMBLY (FOR DRIVER SIDE))

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      D Door P/W Auto SW Driver door power window auto up and down switch signal / ON or OFF ON: Driver door power window auto switch operated
      OFF: Driver door power window auto switch not operated
      -

      OK

      On the Techstream screen, ON or OFF is displayed accordingly.

    NG → See step   5 

    OK: Go to next step 

  3. PERFORM INITIALIZATION (for Driver Side) 
    1. Initialize the power window regulator motor assembly (for driver side). Refer to INITIALIZATION .

    NEXT: Go to next step 

  4. CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION) 
    1. Check that the driver side door power window moves when the auto up and down functions of the multiplex network master switch assembly are operated. Refer to OPERATION CHECK .

      OK

      Driver side auto up and down functions are normal.

    NG → See step   8 

    OK → END (PROBLEM DUE TO INITIALIZATION FAILURE) 

  5. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY 
    1. Replace the multiplex network master switch assembly. Refer to REMOVAL .

    NEXT: Go to next step 

  6. CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION) 
    1. Check that the driver side door power window moves when the auto up and down functions of the multiplex network master switch assembly are operated. Refer to OPERATION CHECK .

      OK

      Driver side auto up and down functions are normal.

    NG → See step   8 

    OK → END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE) 

  7. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY. Refer to  REMOVAL 
  8. REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side). Refer to  REMOVAL