Typical Enabling Conditions
| Monitor runs whenever following DTCs are not present | None |
| Time after engine start | 5 seconds or more |
| Injector driver relay | On |
| Output duty cycle | More than output duty cycle change map value*, and less than 95% |
| Battery voltage | 10.5 V or more |
| Engine switch | On (IG) |
| Starter | Off |
| *: Output duty cycle change map value | - |
| Engine speed is 500 rpm | 5% |
| Engine speed is 2000 rpm | 20% |
| Engine speed is 4000 rpm | 40% |
| Engine speed is 6000 rpm | 60% |
| Engine speed is 8000 rpm | 80% |