MIL Circuit: Procedure
- CHECK MIL CONDITION (WHETHER MIL TURNS OFF)
- Connect Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Check whether any DTCs have been stored. Refer to DTC CHECK / CLEAR . Note them down if necessary.
- Clear DTCs. Refer to DTC CHECK / CLEAR .
- Check if the MIL turns off.
OK
MIL turns off.
OK → REPAIR CIRCUIT INDICATED BY OUTPUT DTC
NG: Go to next step
- CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)
- Disconnect the A6 ECM connector.
- Turn the engine switch on (IG).
- Check the MIL is not illuminated.
OK
MIL is not illuminated.
- Reconnect the ECM connector.
OK → See step 7
NG: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)
- Disconnect the A6 ECM connector.
- Disconnect the J35 combination meter connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open)
Tester Connection Specified Condition W (A6-8) - EFI (J35-12) Below 1 Ω Standard resistance (Check for short)
Tester Connection Specified Condition W (A6-8) or EFI (J35-12) - Body ground 10 kΩ or higher - Reconnect the combination meter connector.
- Reconnect the ECM connector.
OK → REPAIR OR REPLACE COMBINATION METER ASSEMBLY
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK MIL (MIL IS ILLUMINATED)
- Check if the MIL is illuminated when the engine switch is turns on (IG).
OK
MIL is illuminated.
OK → SYSTEM IS OK
NG: Go to next step
- Check if the MIL is illuminated when the engine switch is turns on (IG).
- CHECK HARNESS AND CONNECTOR
- Disconnect the A6 ECM connector.
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Specified Condition W (A6-8) - Body ground 10 to 14 V - Reconnect the ECM connector.
OK → See step 8
NG: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)
- Disconnect the A6 ECM connector.
- Disconnect the J35 combination meter connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open)
Tester Connection Specified Condition W (A6-8) - EFI (J35-12) Below 1 Ω Standard resistance (Check for short)
Tester Connection Specified Condition W (A6-8) or EFI (J35-12) - Body ground 10 kΩ or higher - Reconnect the combination meter connector.
- Reconnect the ECM connector.
OK → REPAIR OR REPLACE COMBINATION METER ASSEMBLY
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
- REPLACE ECM. Refer to REMOVAL