Power Steering System: Calibration: Calibration
- ROTATION ANGLE SENSOR VALUE INITIALIZATION AND TORQUE SENSOR ZERO POINT CALIBRATION NOTE:
Clear the rotation angle sensor calibration value, initialize the rotation angle sensor value, and calibrate the torque sensor zero point if any of the following has occurred:
- The power steering ECU assembly has been replaced.
- The power steering gear assembly has been replaced.
- Steering effort differs between left and right.
- Inspection before calibration
- Connect the Techstream (with CAN VIM) to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Check the IG power supply voltage on the Techstream. Enter the following menus: Chassis / EMPS / Data List.
Tester Display Measurement Item/Range (Display) Inspection Condition Reference Value IG Power Supply ECU power source voltage/
Min.: 0 V, Max.: 20.1531 VEngine switch on (IG) 10 to 14 V Voltage
10 to 14 V
NOTE:If the IG power supply voltage is 10 V or less, calibration cannot be performed. In this case, charge or replace the battery, and then perform calibration.
- Rotation angle sensor calibration value clear, rotation angle sensor value initialization, and torque sensor zero point calibration.NOTE:
- If DTC C1516 (Torque Sensor Zero Point Adjustment Incomplete) is stored, the torque sensor zero point cannot be calibrated. Clear the DTC before starting calibration.
- If DTC C1526 (Rotation Angle Sensor Initialization Incomplete) is stored, the rotation angle sensor value cannot be initialized. Clear the DTC before starting initialization.
- Connect the Techstream (with CAN VIM) to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Follow the procedures on the Techstream to clear the rotation angle sensor calibration value, initialize the rotation angle sensor value, and calibrate the torque sensor zero point.NOTE:
- When initializing the rotation angle sensor value, observe the following to stabilize sensor voltage:
After turning the engine switch on (IG), wait for at least 2.5 seconds before turning the steering wheel. Do not turn the steering wheel quickly.
- The steering wheel will vibrate during torque sensor zero point calibration. Do not touch the steering wheel while it is vibrating or for 2 seconds after it stops.
- When initializing the rotation angle sensor value, observe the following to stabilize sensor voltage: