Home >> Lexus >> 2012 >> LS 460 AWD >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (Diagnostic Codes & Symptom Tests) >> Power Window Control System >> Symptom Tests >> Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch: Procedure

  1. CHECK FOR DTC 
    1. Check for DTCs.
      RESULT:

      Result Proceed to
      DTC is not output A
      B2311 is output B
      B2312 is output C
      B2313 is output D
      LIN communication system DTC output reoccur E

    B → See step   9 

    C → See step   6 

    D → See step   7 

    E → See step   5 

    A: Go to next step 

  2. CHECK MANUAL UP / DOWN FUNCTION 
    1. Check that the manual UP/DOWN function using the multiplex network master switch can operate the driver door power window.

      OK

      Manual UP/DOWN function operates normally.

    NG → See step   8 

    OK: Go to next step 

  3. READ VALUE USING TECHSTREAM 
    1. Use the Data List to check if the master switch is functioning properly.
      MASTER SWITCH:

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      D Door P/W Auto SW Driver side power window auto UP/DOWN switch signal / ON or OFF ON: Driver side power window auto UP/DOWN switch on master switch operated
      OFF: Driver side power window switch on master switch not operated
      -

      OK

      Techstream display changes normally when master switch is operated.

    NG → See step   4 

    OK → See step   10 

  4. REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY. Refer to  REMOVAL 
  5. GO TO LIN COMMUNICATION SYSTEM. Refer to  HOW TO PROCEED WITH TROUBLESHOOTING 
  6. GO TO DTC B2312. Refer to  DTC B2312: Power Window Switch Malfunction  
  7. GO TO DTC B2313. Refer to  DTC B2313: Glass Position Initialization Incomplete  
  8. OTHER PROBLEM. Refer to  Driver Side Power Window does not Operate with Power Window Master Switch  
  9. GO TO DTC B2311. Refer to  DTC B2311: Power Window Motor Malfunction  
  10. REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to  REMOVAL