Valve Body Assembly
VALVE BODY ASSEMBLY
| Shift solenoid valve SL1 | ||
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| Shift solenoid valve SL2 | ||
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| Shift solenoid valve S1 | ||
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body | 15 to 25 °C (59 to 77 °F) | 11 to 15 Ω |
| Shift solenoid valve S3 | ||
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body | 15 to 25 °C (59 to 77 °F) | 11 to 15 Ω |
| Shift solenoid valve S2 | ||
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 15 to 25 °C (59 to 77 °F) | 11 to 15 Ω |
| Shift solenoid valve S4 | ||
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body | 15 to 25 °C (59 to 77 °F) | 11 to 15 Ω |
| Shift solenoid valve SR | ||
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve SR connector terminal - Shift solenoid valve SR body | 15 to 25 °C (59 to 77 °F) | 11 to 15 Ω |
| Shift solenoid valve SLT | ||
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20 °C (68 °F) | 5.0 to 5.6 Ω |
| Shift solenoid valve SLU | ||
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20 °C (68 °F) | 5.0 to 5.6 Ω |