  1. DATA LIST 

    HINT: 

    Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    NOTE:

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Occupant Detection / Data List.
    5. According to the display on the Techstream, read the "Data List".
      OCCUPANT DETECTION

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Passenger Classification Passenger classification / NG, AM50, AF05, Child or OFF NG: Data not determined
      AM50: Adult seated and seat in rear position
      AF05: Adult seated and seat in front position
      Child: Child seated
      OFF: Vacant
      -
      Passenger Buckle SW Buckle switch (passenger side) / Unset, Set or NG Set: Passenger side seat belt fastened
      Unset: Passenger side seat belt unfastened
      NG: Data is not determined
      -
      Pressure sensor output Pressure sensor output / Min.:0, Max.: 255 0 to 210 -
      Filtered pressure sensor output Filtered pressure sensor output / Min.: 0, Max.: 255 38 to 240 If the value is outside the range of Specified Condition for Zero Point Calibration, check whether any objects are placed on the seat cushion and that the seat cushion is fitted correctly.
      Thermistor temperature output Thermistor temperature output / Min.: -40°C (-40°F), Max.: 90°C (194°F) -40 to 85°C
      (-40 to 185°F)
      If the value is outside the range of Specified Condition for Zero Point Calibration, adjust the temperature to the proper range by using the air conditioner, etc.
      Weight threshold Weight threshold / Min.: 0, Max.: 255 36 to 67
      (reference value)
      -
      Filtered belt tension output Filtered belt tension output / Min.: 0, Max.: 255 39 to 229 -
      Empty threshold value from the seat factory Empty threshold value from seat factory / Min.: 0, Max.: 255 38 to 75 -
      Allow threshold Threshold value for adult passenger or not from seat factory / Min.: 0, Max.: 255 43 to 64
      (reference value)
      -
      Number of Present DTC Number of stored trouble codes / Min.: 0, Max.: 255 0 -
      Number of Past DTC Number of past trouble codes / Min.: 0, Max.: 255 0 -