Monitor Strategy
| Related DTCs | P0107: Manifold absolute pressure sensor range check (Low voltage) P0108: Manifold absolute pressure sensor range check (High voltage) |
| Required Sensor/Components (Main) | Manifold absolute pressure sensor |
| Required Sensor/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediately |
| Sequence of Operation | None |