LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2017 >> GS 350 Base, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 4 (Engine Control System - Diagnostics & Circuit Tests) >> SFI System >> EVAP System [10/2015 - 09/2018] >> Monitor Result
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Monitor Result

WARNING: This page is about a different car, the 2019 Lexus GS 300, 2018 Lexus GS 300, 2017 Lexus GS 200t, and 2016 Lexus GS 200t. However, it is still accessible from the selected car via links, so may be relevant.

Refer to detailed information in Checking Monitor Status.

Refer to CHECKING MONITOR STATUS [10/2015 - ]

P0456: EVAPORATIVE SYSTEM / SMALL LEAK

Monitor ID Test ID Scaling Unit Description
$3D $C9 Multiply by 0.001 kPa Test value for small leak
P0455: EVAPORATIVE SYSTEM / GROSS LEAK

Monitor ID Test ID Scaling Unit Description
$3D $CA Multiply by 0.001 kPa Test value for gross leak
P2401: EVAPORATIVE SYSTEM / VACUUM PMP OFF

Monitor ID Test ID Scaling Unit Description
$3D $CB Multiply by 0.001 kPa Test value for leak detection pump stuck OFF
P2402: EVAPORATIVE SYSTEM / VACUUM PMP ON

Monitor ID Test ID Scaling Unit Description
$3D $CD Multiply by 0.001 kPa Test value for leak detection pump stuck ON
P2420: EVAPORATIVE SYSTEM / VENT VALVE OFF

Monitor ID Test ID Scaling Unit Description
$3D $CE Multiply by 0.001 kPa Test value for vent valve stuck OFF
P2419: EVAPORATIVE SYSTEM / VENT VALVE ON

Monitor ID Test ID Scaling Unit Description
$3D $CF Multiply by 0.001 kPa Test value for vent valve stuck ON
P043E: EVAPORATIVE SYSTEM / ORIFICE CLOGGED

Monitor ID Test ID Scaling Unit Description
$3D $D0 Multiply by 0.001 kPa Test value for reference orifice low flow
P043F: EVAPORATIVE SYSTEM / ORIFICE HI-FLW

Monitor ID Test ID Scaling Unit Description
$3D $D1 Multiply by 0.001 kPa Test value for reference orifice high flow
P148D: EVAPORATIVE SYSTEM / PURGE VSV CLOSED

Monitor ID Test ID Scaling Unit Description
$3D $D4 Multiply by 0.001 kPa Test value for purge one way valve stuck open