LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2017 >> GS 350 F Sport, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - Diagnostic Codes (4 Of 7) >> SFI System >> DTC P0420-00: Catalyst System Efficiency Below Threshold Bank 1; DTC P0430-00: Catalyst System Efficiency Below Threshold Bank 2 [09/2016 - ] >> Conditioning For Sensor Testing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Conditioning For Sensor Testing

HINT: 

Perform the operation with the engine speeds and time durations described below prior to checking the waveforms of the air fuel ratio and heated oxygen sensors. This is to activate the sensors sufficiently to obtain appropriate inspection results.

GTY515697Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  1. (a) Connect the Techstream to the DLC3.
  2. (b) Start the engine and warm it up with all the accessories switched off until the engine coolant temperature stabilizes.
  3. (c) Run the engine at an engine speed of between 2500 rpm and 3000 rpm for at least 3 minutes.
  4. (d) While running the engine at 3000 rpm for 2 seconds, and then 2000 rpm for 2 seconds, check the waveforms of the air fuel ratio and heated oxygen sensors using the Techstream.

HINT: 

GTY180176Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002