Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch [10/2014 - ]: Procedure
- READ VALUE USING TECHSTREAM (MASTER SWITCH)
- Read the Data List according to the display on the Techstream.
Refer to DATA LIST / ACTIVE TEST [10/2014 - ]
Body Electrical > Master Switch > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver door power window auto switch signal OFF or ON OFF: Driver door power window auto switch not being operated
ON: Driver door power window auto switch being operated- Body Electrical > Master Switch > Data List
Tester Display D Door P/W Auto SW OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result
Proceed to OK NG
Result:
NG
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY. Refer to REMOVAL [10/2014 - ]
Result:
OK
See step 2
- Read the Data List according to the display on the Techstream.
- READ VALUE USING TECHSTREAM (D-DOOR MOTOR)
- Read the Data List according to the display on the Techstream.
Refer to DATA LIST / ACTIVE TEST [10/2014 - ]
Body Electrical > D-Door Motor > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver door power window auto switch signal OFF or ON OFF: Driver door power window auto switch not being operated
ON: Driver door power window auto switch being operated- Body Electrical > D-Door Motor > Data List
Tester Display D Door P/W Auto SW OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result
Proceed to OK NG
Result:
NG
See step 5
Result:
OK
See step 3
- Read the Data List according to the display on the Techstream.
- PERFORM INITIALIZATION (FOR DRIVER DOOR)
- Initialize the front power window regulator motor assembly LH.
Refer to INITIALIZATION [10/2014 - ]
Result
Proceed to NEXT
Result:
NEXT
See step 4
- Initialize the front power window regulator motor assembly LH.
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated.
Refer to OPERATION CHECK [10/2014 - ]
OK
Driver door auto up and down function is normal.
Result
Proceed to OK NG
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [10/2014 - 05/2019] , or refer to REMOVAL [05/2019 - ]
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated.
- REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
- Replace the multiplex network master switch assembly.
Refer to REMOVAL [10/2014 - ]
Result
Proceed to NEXT
Result:
NEXT
See step 6
- Replace the multiplex network master switch assembly.
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated.
Refer to OPERATION CHECK [10/2014 - ]
OK
Driver door auto up and down function is normal.
Result
Proceed to OK NG
Result:
OK
END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [10/2014 - 05/2019] , or refer to REMOVAL [05/2019 - ]
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated.