Freeze Frame Data [10/2018 - ]
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Lexus UX 250h, 2023 Lexus UX 250h, 2022 Lexus UX 250h, 2021 Lexus UX 250h, and 2020 Lexus UX 250h. However, it is still accessible from the selected car via links, so may be relevant.
- FREEZE FRAME DATA
HINT:
The motor generator control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Select a DTC in order to display its freeze frame data.
- Check the freeze frame data recorded with the DTC.
Powertrain > Motor Generator
Tester Display Measurement Item Range Diagnostic Note Calculate Load Calculate load (value increases in proportion to increase in load) Min.: 0.0%, Max.: 100.0% - Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Cold or warmed-up engine Engine Speed Engine speed Min.: 0 rpm, Max.: 16383 rpm - Vehicle Speed Vehicle speed Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) Stopped, or driving (at low, medium, or high speeds) Intake Air Temperature Intake air temperature Min.: -40°C (-40°F), Max.: 140°C (284°F) - Throttle Position Sensor No. 1 Voltage % Throttle position sensor Min.: 0.0%, Max.: 100.0% - Engine Run Time Elapsed time after starting engine Min.: 0 sec, Max.: 65535 sec After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off. MIL ON Run Distance Drive distance from MIL on Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) - Warmup Cycle Cleared DTC Warmup cycles after DTCs cleared Min.: 0, Max.: 255 - Distance from DTC Cleared Distance driven after DTCs cleared Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) - Battery Voltage Auxiliary battery voltage Min.: 0.00 V, Max.: 16.00 V Auxiliary battery and DC/DC converter condition Ambient Temperature Ambient air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) - Running Time from MIL ON Running time from MIL on Min.: 0 min, Max.: 65535 min - Time after DTC Cleared Time after DTCs cleared Min.: 0 min, Max.: 65535 min - Shift SW Status (N, P Range) Shift lever position sensor ON or OFF - Hybrid/EV Battery System Voltage HV battery voltage Min.: 0.00 V, Max.: 1023.98 V - Hybrid/EV Battery System Current HV battery current Min.: -3276.8 A, Max.: 3276.7 A - Boosting Converter Temperature(Upper) Boost converter temperature (Upper) Min.: 0°C (32°F), Max.: 255°C (491°F) - Boosting Converter Temperature 1(Lower) Boost converter temperature 1 (Lower) Min.: 0°C (32°F), Max.: 255°C (491°F) - Boosting Converter Temperature 2(Lower) Boost converter temperature 2 (Lower) Min.: 0°C (32°F), Max.: 255°C (491°F) - Motor Inverter Temperature Motor inverter temperature Min.: 0°C (32°F), Max.: 255°C (491°F) - Motor U Current(Lower Resolution) Motor U current (Lower resolution) Min.: -3276.8 A, Max.: 3276.7 A - Motor V Current(Lower Resolution) Motor V current (Lower resolution) Min.: -3276.8 A, Max.: 3276.7 A - Motor W Current(Lower Resolution) Motor W current (Lower resolution) Min.: -3276.8 A, Max.: 3276.7 A - Generator U Current(Lower Resolution) Generator U current (Lower resolution) Min.: -3276.8 A, Max.: 3276.7 A - Generator V Current(Lower Resolution) Generator V current (Lower resolution) Min.: -3276.8 A, Max.: 3276.7 A - Generator W Current(Lower Resolution) Generator W current (Lower resolution) Min.: -3276.8 A, Max.: 3276.7 A - Motor ECU Power Supply (For 31V) Motor generator control ECU power supply (for 31V) Min.: 0.00 V, Max.: 4.98 V - Motor ECU Power Supply (For AD0) Motor generator control ECU power supply (for AD0) Min.: 0.00 V, Max.: 4.98 V - Motor ECU Power Supply (For 2.5V) Motor generator control ECU power supply (for 2.5V) Min.: 0.00 V, Max.: 4.98 V - Motor ECU Power Supply (For 2.5V Sub) Motor generator control ECU power supply (for 2.5V sub) Min.: 0.00 V, Max.: 4.98 V - DC/DC Converter Operation State DC/DC converter operation state Min.: 0.00 V, Max.: 4.98 V - DC/DC Converter Output Signal DC/DC converter output signal Min.: 0.00 V, Max.: 4.98 V - DC/DC Converter Output Signal Duty DC/DC converter output signal duty Min.: 0.0 %, Max.: 100.0 % - Motor Revolution Motor (MG2) speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm Motor (MG2) speed - Forward rotation appears as "+"
- Backward rotation appears as "-"
Motor Torque Motor (MG2) torque value Min.: -4096.000 Nm, Max.: 4095.875 Nm When motor (MG2) rotates in "+" direction: - Torque appears as "+" while motor (MG2) discharges
- Torque appears as "-" while motor (MG2) charges
When motor (MG2) rotates in "-" direction:- Torque appears as "-" while motor (MG2) discharges
- Torque appears as "+" while motor (MG2) charges
Motor Control Mode Motor control mode Min.: 0, Max.: 65535 - Motor Carrier Frequency Motor carrier frequency Min.: 0, Max.: 255 - Motor Inverter Shut Down Signal Motor inverter shutdown signal Min.: 0, Max.: 255 - Generator Revolution Generator (MG1) speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm Generator (MG1) speed - Forward rotation appears as "+"
- Backward rotation appears as "-"
Generator Torque Generator (MG1) torque value Min.: -4096.000 Nm, Max.: 4095.875 Nm When generator (MG1) rotates in "+" direction: - Torque appears as "+" while generator (MG1) discharges
- Torque appears as "-" while generator (MG1) charges
When generator (MG1) rotates in "-" direction:- Torque appears as "-" while generator (MG1) discharges
- Torque appears as "+" while generator (MG1) charges
Generator Control Mode Generator control mode Min.: 0, Max.: 65535 - Generator Carrier Frequency Generator carrier frequency Min.: 0, Max.: 255 - Generator Inverter Shut Down Signal Generator (MG1) inverter shutdown signal Min.: 0, Max.: 255 - Inverter Coolant Temperature Coolant (for inverter) temperature Min.: -40°C (-40°F), Max.: 110°C (230°F) - Inverter Input Current Inverter input current Min.: -3276.8 A, Max.: 3276.7 A - Inverter Water Pump Duty Inverter water pump motor driver request duty Min.: 0 %, Max.: 100 % - Inverter Water Pump Revolution Inverter water pump assembly speed Min.: 0 rpm, Max.: 15000 rpm - Collinear Graphic Engine Revolution Col-linear graphic engine revolution Min.: 0 rpm, Max.: 65535 rpm - Motor Resolver After Offset Motor resolver offset value Min.: 0.000 deg, Max.: 358.593 deg - Motor Resolver Offset Value Motor Resolver Offset Value Min.: -250.000 deg, Max.: 249.992 deg - Generator Resolver After Offset Generator resolver offset value Min.: 0.000 deg, Max.: 358.593 deg - Generator Resolver Offset Value Generator resolver offset value Min.: -250.000 deg, Max.: 249.992 deg - VL Voltage High voltage before it is boosted Min.: 0.0 V, Max.: 6553.5 V - VH Voltage High voltage after it is boosted Min.: 0.0 V, Max.: 6553.5 V - Boosting Converter PWM Duty Boost converter PWM duty Min.: 0 %, Max.: 100 % - Boosting Converter Control Mode Boost converter control mode Min.: 0, Max.: 255 - Boosting Converter Carrier Frequency Boost converter signal carrier frequency HI or LO - Boosting Converter Shut Down Signal Boost converter shutdown signal Min.: 0, Max.: 255 - Generate Request Torque Generator (MG1) torque request value Min.: -4096.000 Nm, Max.: 4095.875 Nm - Shift Position Shift position P/R/N/D - Motor Temperature Motor (MG2) temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) - Generator Temperature Generator (MG1) temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) - Short Wave Highest Value Waveform voltage in abnormal insulation detection circuit in battery voltage sensor Min.: 0.00 V, Max.: 4.98 V - Fail Safe Mode Fail safe mode Min.: -128, Max.: 127 - Accelerator Position Accelerator pedal opening angle Min.: 0 %, Max.: 100.0 % - WIN Control Limit Power Charge control wattage sent from battery voltage sensor to hybrid vehicle control ECU Min.: -327.68 kW, Max.: 327.67 kW - WOUT Control Limit Power Discharge control wattage sent from battery voltage sensor to hybrid vehicle control ECU Min.: -327.68 kW, Max.: 327.67 kW - Engine Control Mode Engine control mode Stop, Stop Process, Startup Process, Running - Emergency Shutdown Signal Inverter emergency shutdown ON or OFF - Ready ON Status State of system (READY) ON or OFF - SMR Status SMR status ON or OFF - Generator Resolver Offset Complete Status Generator resolver learning complete status ON or OFF - Generator Inverter High Current(GFINV) Generator (MG1) inverter high current ON or OFF - Generator Inverter Shut Down Status Generator (MG1) inverter shutdown status ON or OFF - Motor Resolver Offset Complete Status Motor resolver learning complete status ON or OFF - PTC Heater Activate Permission Status/Prohibition Signal(IDH) PTC heater ON or OFF - DC/DC Converter Terminate Signal DC/DC converter stop request signal ON or OFF - Motor Inverter High Current(MFINV) Motor inverter high current ON or OFF - Motor Inverter Shut Down Status Motor inverter shutdown ON or OFF - Inverter Input High Voltage(OVH) Inverter input high voltage ON or OFF - Boosting Converter Input High Voltage(OVL) Boost converter input high voltage ON or OFF - Boosting Converter Input High Current(CFINV) Boost converter input high current ON or OFF - Boosting Converter Shut Down Status Boost converter shutdown ON or OFF - Total Distance Traveled Drive total distance Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) - Total Distance Traveled - Unit Drive total distance unit km or mile -