Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [09/2015 - ]: Procedure
- PERFORM INITIALIZATION
- Initialize the power window regulator motor. Refer to INITIALIZATION [09/2015 - ] .
- Check if the power window auto up/down function operates. Refer to OPERATION CHECK [09/2015 - ]
.
OK
Auto up/down function operates.
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
See step 2
- CHECK MOVEMENT OF DOOR GLASS (LOCATION WHERE JAM PROTECTION FUNCTION OPERATES)
- Remove the installation bolt of the door glass and hold the glass by hand. When raising the glass by hand, check that the glass moves smoothly.NOTE:
- Make sure that the door glass fits to the glass run properly.
- Make sure that the glass run is not deformed, and that there is no foreign matter on the glass run.
OK
Door glass moves smoothly.
Result:
OK
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (APPLICABLE LOCATION)
Result:
NG
INSTALL DOOR GLASS AND/OR GLASS RUN PROPERLY (APPLICABLE LOCATION)
- Remove the installation bolt of the door glass and hold the glass by hand. When raising the glass by hand, check that the glass moves smoothly.