| P0335-00 |
Crankshaft Position Sensor "A" |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0335-00: Crankshaft Position Sensor "A"; DTC P0335-31: Crankshaft Position Sensor "A" No Signal [08/2020 - ] |
| P0335-31 |
Crankshaft Position Sensor "A" No Signal |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0335-00: Crankshaft Position Sensor "A"; DTC P0335-31: Crankshaft Position Sensor "A" No Signal [08/2020 - ] |
| P0340-00 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P0340-31: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [08/2020 - ] |
| P0340-31 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P0340-31: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [08/2020 - ] |
| P062F-44 |
Internal Control Module EEPROM Data Memory Failure |
Comes on |
Master Warning Light: Does not come on |
Refer to DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [08/2020 - ] |
| P062F-46 |
Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P062F-46: Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure [08/2020 - ] |
| P06B0-1C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P06D6-1C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P0A00-11 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [08/2020 - ] |
| P0A00-15 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [08/2020 - ] |
| P0A00-1C |
Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [08/2020 - ] |
| P0A08-12 |
DC/DC Converter Status Circuit Short to Battery |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A08-14: DC/DC Converter Status Circuit Short to Ground or Open [08/2020 - ] |
| P0A08-14 |
DC/DC Converter Status Circuit Short to Ground or Open |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A08-14: DC/DC Converter Status Circuit Short to Ground or Open [08/2020 - ] |
| P0A11-12 |
DC/DC Converter Enable Circuit Short to Battery |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A11-14: DC/DC Converter Enable Circuit Short to Ground or Open [08/2020 - ] |
| P0A11-14 |
DC/DC Converter Enable Circuit Short to Ground or Open |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A11-14: DC/DC Converter Enable Circuit Short to Ground or Open [08/2020 - ] |
| P0A1A-47 |
Generator Control Module Watchdog / Safety μC Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P0A1A-49 |
Generator Control Module Internal Electronic Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P0A1B-1F |
Generator Control Module Circuit Intermittent |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A1B-1F: Generator Control Module Circuit Intermittent [08/2020 - ] |
| P0A3F-16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [08/2020 - ] |
| P0A3F-1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [08/2020 - ] |
| P0A3F-21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [08/2020 - ] |
| P0A3F-22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [08/2020 - ] |
| P0A4B-16 |
Generator Position Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [08/2020 - ] |
| P0A4B-1F |
Generator Position Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [08/2020 - ] |
| P0A4B-21 |
Generator Position Sensor Signal Amplitude < Minimum |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum [08/2020 - ] |
| P0A4B-22 |
Generator Position Sensor Signal Amplitude > Maximum |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum [08/2020 - ] |
| P0A60-12 |
Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A60-14 |
Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A60-1C |
Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A60-1F |
Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A63-12 |
Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A63-14 |
Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A63-1C |
Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A63-1F |
Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [08/2020 - ] |
| P0A78-72 |
Drive Motor "A" Inverter Actuator Stuck Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A78-72: Drive Motor "A" Inverter Actuator Stuck Open [08/2020 - ] |
| P0A78-73 |
Drive Motor "A" Inverter Actuator Stuck Closed |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [08/2020 - ] |
| P0A78-9E |
Drive Motor "A" Inverter Stuck On |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [08/2020 - ] |
| P0A7A-72 |
Generator Inverter Actuator Stuck Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A7A-72: Generator Inverter Actuator Stuck Open [08/2020 - ] |
| P0A7A-73 |
Generator Inverter Actuator Stuck Closed |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [08/2020 - ] |
| P0A7A-9E |
Generator Inverter Stuck On |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [08/2020 - ] |
| P0A90-00 |
Drive Motor "A" Performance |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A90-00: Drive Motor "A" Performance [08/2020 - ] |
| P0A92-00 |
Hybrid Generator Performance |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A92-00: Hybrid Generator Performance [08/2020 - ] |
| P0A94-9E |
DC/DC Converter Stuck On |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [08/2020 - ] |
| P0AED-11 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED-15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [08/2020 - ] |
| P0AED-15 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED-15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [08/2020 - ] |
| P0AED-1C |
Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0AED-1C: Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range [08/2020 - ] |
| P0BE5-12 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BE5-14 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BE5-1F |
Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BE5-28 |
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-28: Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BE9-28: Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BED-28: Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" [08/2020 - ] |
| P0BE9-12 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BE9-14 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BE9-1F |
Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BE9-28 |
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-28: Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BE9-28: Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BED-28: Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" [08/2020 - ] |
| P0BED-12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BED-14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BED-1F |
Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BED-28 |
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BE5-28: Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BE9-28: Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BED-28: Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" [08/2020 - ] |
| P0BFD-62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BFD-62: Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure"; DTC P1C67-1F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0BFF-1D |
Drive Motor "A" Circuit Current Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0BFF-1D: Drive Motor "A" Circuit Current Out of Range [08/2020 - ] |
| P0C19-00 |
Drive Motor "A" Execution Torque Performance |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C19-00: Drive Motor "A" Execution Torque Performance [08/2020 - ] |
| P0C38-11 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [08/2020 - ] |
| P0C38-15 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [08/2020 - ] |
| P0C38-1C |
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C38-1C: DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range [08/2020 - ] |
| P0C3D-11 |
DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [08/2020 - ] |
| P0C3D-15 |
DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [08/2020 - ] |
| P0C3D-1C |
DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C3D-1C: DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range [08/2020 - ] |
| P0C50-13 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C50-16 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C50-17 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C50-1F |
Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C5A-13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C5A-16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C5A-17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C5A-1F |
Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C64-13 |
Generator Position Sensor Circuit "A" Circuit Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C64-16 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C64-17 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C64-1F |
Generator Position Sensor Circuit "A" Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C69-13 |
Generator Position Sensor Circuit "B" Circuit Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C69-16 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C69-17 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [08/2020 - ] |
| P0C69-1F |
Generator Position Sensor Circuit "B" Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [08/2020 - ] |
| P0C79-17 |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0C79-17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold [08/2020 - ] |
| P0CA3-00 |
DC/DC Converter Step Up Voltage Performance |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0CA3-00: DC/DC Converter Step Up Voltage Performance [08/2020 - ] |
| P0D2D-16 |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent [08/2020 - ] |
| P0D2D-17 |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent [08/2020 - ] |
| P0D2D-1F |
Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent [08/2020 - ] |
| P0D33-19 |
DC/DC Converter Circuit Current Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [08/2020 - ] |
| P0DFA-62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C69-1F: Generator Phase U-V-W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E00-12 |
Generator Phase U Current Sensor Circuit Short to Battery |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E00-14 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E00-1F |
Generator Phase U Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E00-28 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [08/2020 - ] |
| P0E04-12 |
Generator Phase V Current Sensor Circuit Short to Battery |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E04-14 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E04-1F |
Generator Phase V Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E04-28 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [08/2020 - ] |
| P0E08-12 |
Generator Phase W Current Sensor Circuit Short to Battery |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E08-14 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E08-1F |
Generator Phase W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E08-28 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [08/2020 - ] |
| P0E31-16 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [08/2020 - ] |
| P0E31-17 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [08/2020 - ] |
| P0E31-1F |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [08/2020 - ] |
| P0E51-11 |
DC/DC Converter Current Sensor Circuit Short to Ground |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E51-15 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E51-1F |
DC/DC Converter Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [08/2020 - ] |
| P0E51-28 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E51-28: DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [08/2020 - ] |
| P0E51-2A |
DC/DC Converter Current Sensor Signal Stuck In Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E51-2A: DC/DC Converter Current Sensor Signal Stuck In Range [08/2020 - ] |
| P0E57-17 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E57-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold [08/2020 - ] |
| P0E58-11 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Ground |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E58-11: DC/DC Converter Temperature Sensor 2 Circuit Short to Ground; DTC P0E58-15: DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open [08/2020 - ] |
| P0E58-15 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E58-11: DC/DC Converter Temperature Sensor 2 Circuit Short to Ground; DTC P0E58-15: DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open [08/2020 - ] |
| P0E58-1C |
DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E58-1C: DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range [08/2020 - ] |
| P0E71-00 |
Generator Execution Torque Performance |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0E71-00: Generator Execution Torque Performance [08/2020 - ] |
| P1C2A-1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P1C2A-49 |
Generator A/D Converter Circuit Internal Electronic Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P1C2B-1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P1C2B-49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P1C2E-46 |
Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P1C2E-46: Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure [08/2020 - ] |
| P1C5D-19 |
Drive Motor "A" Inverter Circuit Current Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [08/2020 - ] |
| P1C5F-19 |
Generator Inverter Circuit Current Above Threshold |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [08/2020 - ] |
| P1C60-1F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P1C62-1F |
Generator Control Module Offset Power Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P1C64-1F |
Generator Control Module Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [08/2020 - ] |
| P1C65-1F |
Generator Control Module Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [08/2020 - ] |
| P1C67-1F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0BFD-62: Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure"; DTC P1C67-1F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [08/2020 - ] |
| P1C69-1F |
Generator Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C69-1F: Generator Phase U-V-W Current Sensor Circuit Intermittent [08/2020 - ] |
| P1CA5-1D |
Hybrid Generator Circuit Current Out of Range |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CA5-1D: Hybrid Generator Circuit Current Out of Range [08/2020 - ] |
| P1CAC-49 |
Generator Position Sensor Internal Electronic Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [08/2020 - ] |
| P1CAD-49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [08/2020 - ] |
| P1CAF-38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [08/2020 - ] |
| P1CB0-38 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [08/2020 - ] |
| P1CB5-9E |
DC/DC Converter Voltage Sensor "A"(VL) Stuck On |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CB5-9E: DC/DC Converter Voltage Sensor "A"(VL) Stuck On [08/2020 - ] |
| P1CB6-9E |
Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CB6-9E: Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On [08/2020 - ] |
| P1CCC-96 |
DC/DC Converter Enable Component Internal Failure |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P1CCC-96: DC/DC Converter Enable Component Internal Failure [08/2020 - 08/2021] |
| P1CFF-62 |
Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P1CFF-62: Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure [08/2020 - ] |
| P3124-1F |
Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
Does not come on |
Master Warning Light: Does not come on |
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent; DTC P3124-87: Lost Communication between Drive Motor "A" and HV ECU Missing Message [08/2020 - ] |
| P3124-87 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent; DTC P3124-87: Lost Communication between Drive Motor "A" and HV ECU Missing Message [08/2020 - ] |
| P3133-83 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P3133-86 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P3133-87 |
Communication Error from Generator to Drive Motor "A" Missing Message |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P3134-83 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P3134-86 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P3134-87 |
Communication Error from Drive Motor "A" to Generator Missing Message |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [08/2020 - ] |
| P314F-1F |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Comes on |
Master Warning Light: Comes on |
Refer to DTC P314F-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [08/2020 - ] |
| P3153-1D |
DC/DC Converter Current Sensor Circuit Current Out of Range |
Does not come on |
Master Warning Light: Comes on |
Refer to DTC P3153-1D: DC/DC Converter Current Sensor Circuit Current Out of Range [08/2020 - ] |
| U0100-87 |
Lost Communication With ECM/PCM "A" Missing Message |
Comes on |
Master Warning Light: Comes on |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-87: Lost Communication With Brake System Control Module(ch2) Missing Message [08/2020 - ] |
| U0293-87 |
Lost Communication With Hybrid Powertrain Control Module Missing Message |
Comes on |
Master Warning Light: Comes on |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-87: Lost Communication With Brake System Control Module(ch2) Missing Message [08/2020 - ] |
| U1170-87 |
Lost Communication With Brake System Control Module(ch2) Missing Message |
Comes on |
Master Warning Light: Comes on |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-87: Lost Communication With Brake System Control Module(ch2) Missing Message [08/2020 - ] |