Jam Protection Function does not Operate [01/2017 - ]: Procedure
- PERFORM INITIALIZATION (APPLICABLE LOCATION)
- Initialize the power window regulator motor assembly (applicable location).
Refer to INITIALIZATION [01/2017 - ]
Result
Proceed to NEXT
Result:
NEXT
See step 2
- Initialize the power window regulator motor assembly (applicable location).
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check if the power window auto up and down function operates normally.
Refer to OPERATION CHECK [01/2017 - ]
OK
Auto up and down function is normal.
Result
Proceed to OK NG
Result:
NG
GO TO OTHER PROBLEM. Refer to PROBLEM SYMPTOMS TABLE [01/2017 - ]
Result:
OK
See step 3
- Check if the power window auto up and down function operates normally.
- CHECK JAM PROTECTION FUNCTION OPERATING RANGE
- Check if the jam protection function operates normally for the applicable power window.
HINT:
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
OK
Jam protection function operates normally.
Result
Result Proceed to OK A NG (Driver door power window) B NG (Front passenger door power window) C
Result:
A
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
B
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH. Refer to REMOVAL [01/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
Result:
C
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY RH. Refer to REMOVAL [01/2017 - 05/2023] , or refer to REMOVAL [05/2023 - ]
- Check if the jam protection function operates normally for the applicable power window.